TROUBLESHOOTING
HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at
Seite 41
METALLDREHMASCHINE / METAL TURNING LATHE ED 300FD
16
TROUBLESHOOTING
Disconnect the machine from the power supply prior to any checks performed
at the machine itself !
Trouble
Possible cause
Solution
Machine does not start
machine is not connected
fuse or contactor broken
cord is damaged
Check all electric connections
Change fuse, activate the contac-
tor
Replace cable
Machine does not come
up to speed
Extension cord too long
Not suitable for existing motor
voltage
weak power grid
Exchange on optional extension
cable,see wiring box cover for cor-
rect wiring
Contact the electrician
The machine vibrates
strongly
Stands on uneven ground
Engine mounting is loose
Reconstitute
Tighten the fixing screws
Turning tool has a short
life
Hard casting skin
At high cutting speed
Too large an advance
Insufficient cooling
Cast skin before break
Select cutting speed lower
Lower delivery (finishing allow-
ance not more than 0.5 mm)
More cooling
Cutting breaks out
Wedge angle is too small (heat
congestion)
Grinding cracks by improper coo-
ling
Excessive play in the spindle bear-
ings (vibrations occur)
Choose wedge angle greater
uniformly cool
Adjust play in the spindle bear-
ings. If necessary, replace tapered
roller bearings.
Twisted threads wrong
Thread turning tool is incorrectly
clamped or sanded wrong
Incorrect pitch
Wrong diameter
Setting the turning tool on center
Grind angle correctly
Set the correct slope
Pre-turns workpiece to exact di-
ameter