Page | 20
H-
RTK
Change the output frequency of mobile station
In the default frequency of position information output by Rover module is 1HZ. If you need to speed
up the position output frequency, you can enter the Messages view -> ubx -> cgf-> RATE setting and
change the Measurement Period. For example, change the Measurement Period to 200ms and the
Measurement output Frequency will rise to 5HZ.
To make sure the current Settings are saved, go to the Messages view -- > ubx-> CFG (Configuration)
page and click
Save Current Configuration
option, and then click
Send
.