9
Important:
Operate refrigerator only when level. Level
the refrigerator with two torpedo levels. Place the levels in a
perpendicular orientation on the bottom shelf of the refrigerator.
The bubbles should be at least half-way inside the circles.
CAUTION:
Operating the refrigerator off-level separates chemicals,
causing them to crystallize and block the circulation action
of the cooling unit. Damage is cumulative and irreversible.
WARNING:
DO NOT use the refrigerator an ammonia smell is present inside or outside of the refrigerator, or if a
yellowish substance appears inside or at the outside access compartment. This can be an indication of
a refrigerant leak. Contact an authorized repair facility.
For the refrigerator to operate:
House batteries must be charged.
The primary propane tank valve must be on, or an
AC
source must be available.
The refrigerator 120 Volt AC cord(s) must be plugged in (located outside behind refrigerator access door).
If controls do not light up, check the house batteries charge status or see if the 12 Volt DC wires are
plugged into the refrigerator circuit board (located outside behind refrigerator access door).
Control Panel
The mode switch starts and shuts off the refrigerator
:
Push the selector switch to the Auto position to operate the refrigerator in Auto mode. This feature selects
AC
over propane operation. If
AC
discontinues, the refrigerator switches to propane operation.
Push the selector switch to the Gas position to operate the refrigerator on propane.
The temperature switch control adjusts the temperature (9 is coldest) of the freezer and the fresh food
compartment.
NOTE:
If the energy supply is interrupted, the control panel
will display a fault code. See the OEM manual for fault
codes and troubleshooting information.
Control Panel - Two Door
ON/OFF Button
- Turns the refrigerator on or off.
- Push the
ON/OFF
button to start the refrigerator in Auto mode.
- Push and hold the
ON/OFF
button for two seconds to shut it off.
LED Display
- This screen is used for mode, temperature and fault code display.
TEMP SET Button
- Adjusts the temperature.
- To adjust push and hold the
TEMP SET
button.
- Number
“9”
is the coldest setting.
MODE Button
- Controls the operation mode of the refrigerator.
- Push and hold the
MODE
button to select between Automatic AU, AC or LP operation.
Manual Mode:
When one of the two manual modes is selected:
1.
AC
= The refrigerator is operating on AC electric.
2.
LP
= The refrigerator is operating on propane.
020295
Leveling the refrigerator.
030864c
030864i
Control panel for single door