16
V125T/July 2020/V1.1
4.1.3
Fitting the cooling system
Description of the cooling system.
The coolant system consists of the following items:-
1.
Coolant bottle
2.
Flow adjustment tap
3.
Coolant tube
4.
MT3 Arbor with integral coolant collar
5.
Stay Bar
The coolant system has a cutter holder (4) with an integral collar which allows coolant to be fed
down through the centre of the cutter whilst rotating.
The collar is prevented from rotating by the stay bar (5).
Coolant is stored in the coolant bottle (1), the flow is regulated by the tap (2) and fed to the cutter
holder collar by means of a flexible tube (3).
The coolant bottle is attached to the main stand by means of a bracket.
[image 6]
–
Guard not shown.