DEVICE DESCRIPTION

1.  red indicator light

2.  yellow indicator light

3.  green indicator light

4. display

5.  the „ON/OFF” button

6.  wooden profi le detection button, long press on switches to exact/deep mode.

7.  metal and wire detection button

8.  detection area

9.  battery cover. 

DISPLAY

1.  Exact mode where objects are detected (maximum 

detection depth is up to 20mm)

2.  Currently selected function to detect electrical cables, 

wood profi les or metal.

3.  Deep mode where objects are detected (max detec-

tion depth is up to 38mm)

4.  Magnetic or ferro-magnetic object detection icon

5.  Battery level indicator

6.  Sound icon (the sound can be switched on/off while 

pressing buttons 6 and 7 simultaneously).

7.  Detected metal depth indicator (depth refers to the 

distance between the centre of the detection zone and 

the detected object)

8.  In wood profi le detection mode, a display icon is 

displayed indicating the border (edge) or center of the 

measured object to the center line of the instrument; 

in metal and AC mode, only the Center icon is display-

ed in metal mode.

9.  Signal strength indicator

Содержание HT4M340

Страница 1: ...awy Prawo o pomiarach OG LNE WARUNKI BEZPIECZE STWA W zakresie w a ciciela i u ytkownika jest przeczytanie zrozumienie i przestrze ganie poni szych zasad WA NE Prosz przeczyta t instrukcj uwa nie pros...

Страница 2: ...cja wykrywania przewod w elektrycznych profili drewnianych lub metalu 3 Tryb g boki w kt rym wykrywane s obiekty max g boko wykrywania wynosi do 38mm 4 Ikona wykrywania przedmiotu magnetycznego albo f...

Страница 3: ...wiercenia sufitu i pod ogi pi owania nale y zwr ci uwag na czynniki zewn trzne takie jak konstrukcja budynku Aby uzyska najlepszy efekt skanowania unikaj noszenia pier cionk w lub zegark w podczas kor...

Страница 4: ...gna y pola elektrycznego wi c podczas testowania na tego typu powierzchniach mo e to wywiera wp yw na wykrywanie sygna u pr du przemiennego Przewody pod napi ciem mo na atwiej wykry gdy s pod czone do...

Страница 5: ...bezpiecznych czynno ci Pami taj aby od czy zasilanie gaz i wod przed wywierceniem otwor w lub ko k w w cian Maksymalna g boko skanowania 50 mm 220 V przy 50 Hz 110 V przy 60 Hz Wpewnychwarunkach np za...

Страница 6: ...ufacturer does not assume any liability for damage caused by improper use The device is not a measuring device within the meaning of the Measurement Law GENERAL SAFETY CONDITIONS It is within the scop...

Страница 7: ...tly selected function to detect electrical cables wood profiles or metal 3 Deep mode where objects are detected max detec tion depth is up to 38mm 4 Magnetic or ferro magnetic object detection icon 5...

Страница 8: ...etector Metal can cause inaccurate testing Move the tool evenly across the surface without lifting it or changing the pressure applied The tool must always touch the surface during the scan Make sure...

Страница 9: ...lacing your hand on the wall next to the detector can help eliminate static and inductive electricity The signal strength of a live cable depends on the cable position Therefore take further measureme...

Страница 10: ...nd switched on When electrical cables are detected the device sometimes triggers an alarm This is due to high humidity or strong static elec tricity in the wall you can calibrate the device by pressin...

Страница 11: ...Ger t ist kein Messger t im Sinne des Eich und Messgesetzes ALLGEMEINE SICHERHEITSBEDINGUNGEN Es ist Sache des Eigent mers und des Benutzers die folgenden Regeln zu lesen zu verstehen und einzuhalten...

Страница 12: ...nnungsfunktion elektri sche Leitungen Holzprofile oder Metall 3 DEEP MODE Objekte k nnen bis zur einer maxima len Tiefe von 20 mm erkannt werden 4 Symbol magnetische oder ferro magnetische Objekte 5 B...

Страница 13: ...n m ssen Sie externe Faktoren wie den Bau des Geb udes ber cksichtigen Um das beste Ergebnis zu erzielen Vermeiden Sie das Tragen von Ringen oder Uhren wenn Sie den Detektor verwenden Metallische Gege...

Страница 14: ...lossen und eingeschaltet werden Das Signal beim Erkennen von stromf hrenden Leitungen breitet sich von beiden Seiten aus was darauf hinweist dass der Sensor einen viel gr eren Bereich als die tats chl...

Страница 15: ...tet werden Das Ger t l st manchmal einen Alarm aus wenn es die elektrischen Leitungen erkennt Dies ist auf hohe Luftfeuchtigkeit oder starke statische Elektrizit t in der Wand zur ckzuf hren Sie k nne...

Страница 16: ...16 Adres producenta Adresse des Herstellers Manufacturer s Address GTV Poland Sp z o o Sp k ul Przejazdowa 21 05 800 Pruszk w RU HT4M340 8...

Страница 17: ...17 Adres producenta Adresse des Herstellers Manufacturer s Address GTV Poland Sp z o o Sp k ul Przejazdowa 21 05 800 Pruszk w 1 2 3 4 5 6 7 8 9 1 20 2 3 38 4 5 6 6 7 7 8 9...

Страница 18: ...Adres producenta Adresse des Herstellers Manufacturer s Address GTV Poland Sp z o o Sp k ul Przejazdowa 21 05 800 Pruszk w 100 80 50 4 2 40 20 38 5 0 85 RH 0 60 RH 100C 500C 200C 700C 1x9 V 6 147 68 2...

Страница 19: ...19 Adres producenta Adresse des Herstellers Manufacturer s Address GTV Poland Sp z o o Sp k ul Przejazdowa 21 05 800 Pruszk w ON OFF 5 9 7 9 100 7 9 AC 18 20 38...

Страница 20: ...20 Adres producenta Adresse des Herstellers Manufacturer s Address GTV Poland Sp z o o Sp k ul Przejazdowa 21 05 800 Pruszk w 1 3 Edge 8 Edge 8 Edge 8 Edge 8 50 220 50 110 60 7...

Страница 21: ...21 Adres producenta Adresse des Herstellers Manufacturer s Address GTV Poland Sp z o o Sp k ul Przejazdowa 21 05 800 Pruszk w 7...

Страница 22: ...22 Adres producenta Adresse des Herstellers Manufacturer s Address GTV Poland Sp z o o Sp k ul Przejazdowa 21 05 800 Pruszk w...

Страница 23: ...23 Adres producenta Adresse des Herstellers Manufacturer s Address GTV Poland Sp z o o Sp k ul Przejazdowa 21 05 800 Pruszk w...

Страница 24: ...24 Adres producenta Adresse des Herstellers Manufacturer s Address GTV Poland Sp z o o Sp k ul Przejazdowa 21 05 800 Pruszk w...

Отзывы: