Fault
Possible cause
Actions
Steam generator does not heat up
Faulty or not connected temperature
sensor
Check and replace the temperature sensor
The reason is temperature fuse
Unscrew the lid under the bottom plate, press again
temperature fuse (STB, brass)
(See
fi
gure S.23)
Water supply is blocked
Open water supply
Water supply is blocked
Clean anti-residue sieve at the solenoid valve
Anti-calc period reached
Start the anti-calc process
The whole device without voltage
The reason is FI fuse
Turn on the FI fuse once again
The reason is pre-security
Turn on the pre-security once again
There is water in the steam jet
Magnetic valve does not close properly
Check the magnetic valve
There is limescale in the device
Anti-calc process should be started
Содержание SteamBox 1800
Страница 104: ...RU 104 03 05 C 200 03 06 2 x 0 5 2 2 x 1 5 2 4 x 0 25 2 3 x 1 5 2 2 x 1 5 2 03 07 35 45 03 08 HT DN 40...
Страница 107: ...RU 107 04 HOESCH HOESCH HOESCH 04 01 402 8 4 334 88 1000 1 2 3 1 2...
Страница 108: ...RU 108 04 02 8 50 9 5m 04 03 3 2 1 4 134627 1 134007 2 13721601 3 R1 1 4 134014 4 R1 1 4 35...
Страница 111: ...RU 111 SteamBox 420 630 900 1800 08 08 01 08 02 menu exit 08 02 1 menu 0 40 20...
Страница 113: ...RU 113 08 07 4 1 4 menu 1 24 Standby 08 08 3 09 20 103 menu menu ok 103 10 15 15 40 o 50 C 2 3 HOESCH o 40 50 C...
Страница 114: ...RU 114 11 STB S 107 O FI FI...
Страница 118: ...CN 118 03 05 200mm 03 06 2 x 0 5 mm2 2 x 1 5 mm2 4 x 0 25 mm2 3 x 1 5 mm2 2 x 1 5 mm2 03 07 35mm 45 03 08 HT DN 40...
Страница 121: ...CN 121 04 HOESCH HOESCH 04 01 402 8 4 334 88 1000 1 2 3 1 2...
Страница 122: ...CN 122 04 02 8 50 9 5m 04 03 3 2 1 4 134627 1 134007 2 13721601 3 R1 1 4 134014 4 R1 1 4 35...
Страница 123: ...CN 123 05 27 06 R1 2 1 2 3 5 6 4 2 m 1 dm 2 5x1mm 2 3 1 2 1 8 4 CU 35mm x 1 2 5 6...
Страница 125: ...CN 125 SteamBox 420 630 900 1800 08 08 01 08 02 08 02 1 0 40 20...
Страница 127: ...CN 127 08 07 1 4 menu 1 24 OK 08 08 3 09 20 117 OK 117 10 15 15 40 50 15 2 3 Hoesch 40 50 11 STB S 121 FI FI...