7. Electrical Installations 123
The battery circuit breaker must be
on
when using the
vehicle home and whilst driving.
When the circuit breaker is open, the electrical input
stage will
not
engage automatically.
If the battery circuit breaker has been switched on for a
longer period of time, you may lose your customised radio
and/or sat nav device settings. These settings must then
be entered again.
The battery charger is directly connected to the ancillary bat-
tery so that the ancillary and starter batteries can be charged
even if the battery circuit breaker is switched on.
The battery sensor* continues to be activated even if the
battery circuit breaker has been opened.
To keep the batteries charged even when not in use, it is
mandatory that the vehicle be connected to a 230V mains
connection every 6 weeks. Recharging should be carried out
for at least 24 hours.
Charger CA-360, 25 A power charging module
The charger supplies the batteries with electric power when
there is bus-powered mains operation.
As they heat up, the charger reduces its power output to
ensure that there is no chance of overheating.
Das Ladegerät ist am Beifahrersitz von hinten zugänglich.
The fan on the battery charger can be regulated manually.
Please refer to the descriptions for the battery menu on
the TFT control panel.
Battery charger