To add the trigger logic to the logger configuration, open the tab
Logger
and select the
created trigger signals in fields
Start Trigger
(
1
) and
Stop Trigger
(
2
).
Fig. 21
Add trigger logic to logger configuration
►
To start the logging before the trigger, define a
PreTrigger
time.
→
Data is written to a ring buffer and in case of the trigger, the messages are traced back
for the specified time and the logging is started from that point of time.
7.2.3
Creating a Configuration with Bus Description File
With the ACT CAN and CAN FD bus description files (e.g. in CANdB format) can be assigned to
the respective CAN busses. Bus description files allow access to the signals and the possibility to
log individual signals (instead of complete messages) as well as the possibility to use signal values
(e.g. a defined engine speed) on a physical layer (e.g. 2500 rpm instead of 24 hex) as trigger. Log
files for configuration with bus description files are stored in MDF format.
►
Make sure, that the required software is installed (see
) and that
the CANnector Log is connected (see
►
Start the ACT tool.
►
Open menu
File
and select
New
.
→
Wizard to create a new logger project is opened.
Fig. 22
ACT wizard