27 (36)
►
Connect the logic with drag and drop (
3
).
As minimum a threshold and a trigger function block are needed (the threshold is given on physical level).
To stop the logging after a certain time, for example, add a timer and a further trigger. The various
function blocks can be combined freely. Several messages can be used as input signal and several trigger
outputs can be created.
To change the properties of a trigger function block, right-click on the function block and select
Properties
(e.g. the default value of the input signal).
►
To add the trigger logic to the logger configuration, open the tab
Logger
and select the
created trigger signals in fields
Start Trigger
(
1
) and
Stop Trigger
(
2
).
Fig. 28
Add trigger logic to logger configuration
►
To start the logging before the trigger, define a
PreTrigger
time.
→
Data is written to a ring buffer and in case of the trigger, the messages are traced back
for the specified time and the logging is started from that point of time.
CANnector Log User Manual
4.01.0091.21000 1.1 en-US