![HME 6700HD Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/hme/6700hd/6700hd_installation-instructions-manual_2141478034.webp)
EQUIPMENT INST
ALLA
TION
27
Accessing the Bridge with Ethernet
1. Connect all System 485 devices and power ON, but
DO NOT
connect the 485 to the bridge yet.
2. Connect all the network cables to bases and bridge, connect them to the network switch but
DO NOT
power on the bases at this time.
3. Connect the laptop to the HME network switch via a network (CAT5) cable. This should be the
same network switch connecting the Sonic Bridge and base stations.
4.
Configure the laptop IP address to communicate with the Sonic Bridge. The recommended
address that should be used for the laptop is 10.xx.xx.55. The Bridge IP address is
10.xx.xx.2
,
where the middle two octets are the store number (Ex:
Store 1392
has the address
10.13.92.2
).
Refer to label on front of the bridge.
5.
Configure the “Subnet mask” for the laptop to be
255.255.255.128
. The “Default Gateway”
should be left blank.
6. Go to
Bridge Power Up
(next page) to continue setup.
Sections
Содержание 6700HD
Страница 1: ...SYS6700HD Drive Up Communication System Installation Instructions HME 400G754 Rev D 4 26 17...
Страница 2: ......
Страница 7: ......
Страница 18: ...EQUIPMENT INSTALLATION 11 Figure 3 Typical equipment locations Sections 1 2 3 4 5 6 7 8 9 10 11 12...
Страница 62: ...SYSTEM 6700HD BLOCK DIAGRAM Figure 18 System 6700HD Block Diagram 55...
Страница 63: ...Figure 19 RS485 Digital Communications Link RS485 DIGITAL COMMUNICATION LINK 56 56...
Страница 68: ...Figure 24 Power Supplies WIRING DIAGRAM FOR POWER SUPPLIES 61 61...