![HME 6700HD Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/hme/6700hd/6700hd_installation-instructions-manual_2141478026.webp)
EQUIPMENT INST
ALLA
TION
19
5.5.1 Connect Base Station Power Supplies
Remote Display circuit board
S1 Switch Settings
Switch
Base Station
#1
Base Station
#2
Base Station
#3
Base Station
#4
1
OFF
OFF
ON
ON
2
OFF
ON
OFF
ON
3
ON – Monitor number of customers in queue, alternating with wait time.
OFF – Monitor Base Station connection status
4
Both “ON” – RS485 Termination ON
Both “OFF” – RS485 Termination OFF
5
6
NOT USED
7
NOT USED
8
NOT USED, Reserved for Development
●
S1 switches 1 and 2 are used to set the Remote Display addresses.
●
S1 switch 3 is used to select what data will be shown on the display.
●
S1 switches 4 and 5 used to turn RS485 BIAS and termination ON.
●
S1 switches 6 - 8 are not used.