![HME 6700HD Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/hme/6700hd/6700hd_installation-instructions-manual_2141478024.webp)
EQUIPMENT INST
ALLA
TION
17
5.4.1 Connect Base Station Power Supplies
Figure 9. Router DIP switch
●
S2 switches 1 through 3 are used to set the Router addresses.
NOTE
: Each Router must have a separate address.
●
S2 switches 4 and 5 are used to set the RS485 bias (used only if the router is
the last device on the RS485 line).
●
S2 switches 6 and 7 are used to select outbound audio options.
●
S2 switch 8 is used for diagnostics.
●
R18 is for queue tone volume of the ceiling speaker.
●
R21 is for the ring-back tone volume for the stalls and menus outside (when
switch 8 is set to ON).
S2 Switch Settings
Switch
Function - Set Router Physical Address
Router
#1
OP
0 - 15
Router
#1
OP
16 - 31
Router
#1
OP
32 - 47
Router
#1
OP
48 - 63
1
OFF*
OFF
OFF
OFF
2
OFF*
OFF
ON
ON
3
OFF*
ON
OFF
ON
4
4 & 5 = OFF - RS485 Bias is OFF
4 & 5 = ON - RS485 Bias is ON
5
6
OFF - Speaker Used*
ON - Handset used
7
OFF - Aux Audio*
ON - Msg Repeater
8
OFF - Normal*
ON - Diagnostic
*factory setting
Sections
Содержание 6700HD
Страница 1: ...SYS6700HD Drive Up Communication System Installation Instructions HME 400G754 Rev D 4 26 17...
Страница 2: ......
Страница 7: ......
Страница 18: ...EQUIPMENT INSTALLATION 11 Figure 3 Typical equipment locations Sections 1 2 3 4 5 6 7 8 9 10 11 12...
Страница 62: ...SYSTEM 6700HD BLOCK DIAGRAM Figure 18 System 6700HD Block Diagram 55...
Страница 63: ...Figure 19 RS485 Digital Communications Link RS485 DIGITAL COMMUNICATION LINK 56 56...
Страница 68: ...Figure 24 Power Supplies WIRING DIAGRAM FOR POWER SUPPLIES 61 61...