Bridge Power Up
1. Power on the Bridge, and wait 20 seconds for a full boot up.
2. Connect to the Bridge Website.
3. Click on
Devices.
A list of bases should not be displayed. The bases should still be powered off.
4. Power up base 1, wait 15-20 seconds then click on
Devices
to refresh the page. The first base
should show as
ONLINE
. Once listed as online, repeat for each base.
5. Watch each base status screen, and wait for
NDP
to change from “–” to “
✔
”, and then continue to
power up the next base.
Examples displayed below:
Base 1 powered on and connected
a)
If you’re connected to the Bridge
via USB
, enter
192.168.7.2
in your
browser’s address bar to view the Sonic Bridge website.
b) If connected
via Ethernet
, enter “
http://10.xx.xx.2
” in the browser’s
address bar. The middle two octets are the store number (ex:
Store 1392
has
the address
10.13.92.2
). The Sonic Bridge website will appear on-screen.
c) No information will be displayed in the
Baseline
section at this time.
Sections
Содержание 6700HD
Страница 1: ...SYS6700HD Drive Up Communication System Installation Instructions HME 400G754 Rev D 4 26 17...
Страница 2: ......
Страница 7: ......
Страница 18: ...EQUIPMENT INSTALLATION 11 Figure 3 Typical equipment locations Sections 1 2 3 4 5 6 7 8 9 10 11 12...
Страница 62: ...SYSTEM 6700HD BLOCK DIAGRAM Figure 18 System 6700HD Block Diagram 55...
Страница 63: ...Figure 19 RS485 Digital Communications Link RS485 DIGITAL COMMUNICATION LINK 56 56...
Страница 68: ...Figure 24 Power Supplies WIRING DIAGRAM FOR POWER SUPPLIES 61 61...