Boiler Model
Parameter
Unit
SF11 Compact
SF15 Compact
Maximum boiler temperature
o
C
85
Recommended boiler temperature
o
C
65 ÷ 80
Return water min. temperature
o
C
55
Average flue temperature at max. output
o
C
105
120
Average flue temperature at min. output
o
C
55
55
Maximum recommended flue temperature
o
C
180
Flue volume flow at nominal output
g/s
7
10
Flue volume flow at min. output
g/s
3
3
CO emission at nominal output (for 10% O
2
)
mg/m
3
180
98
CO emission at min. output (for 10% O
2
)
mg/m
3
329
180
CO emission at nominal output (for 13% O
2
)
mg/m
3
133
71
CO emission at nominal output (for 13% O
2
)
mg/m
3
240
131
Chimney draft
Pa/mbar
1÷8 / 0.01 ÷ 0.08
Noise level
dB
below 75
Supply voltage
1 PEN ~ 50Hz 230V TN-S
Insulation
IP 20
Power consumption at nominal output
W
40
45
Power consumption at minimum output
W
20
25
Maximum power consumption – controller, fan,
motoreducer
W
115
115
Power consumption – igniter
W
300
300
Power consumption - in stand-by mode
W
3
3
Ambient temperature
o
C
15 ÷ 40
Ambient relative humidity
%
10 ÷ 90
relative humidity without condensation
Dispenser volume
dm
3
50
Ash pan capacity
dm
3
7
Exhaust fan
model
AACO ST73M
Z-A RH15Z
Motoreducer
model
T3 S C9-150 5.3
T3 S C9-100 2.0
Table No. 7. Dimensions and technical data of Smart Fire SF11 Compact and SF15 Compact boiler.
SMART FIRE BOILER User Manual