3.1.
Function I/O
Description:
Standard equipment has function I/O of 8IN/8OUT, which are all in the D-SUB 44P connector.
Function I/O List
Table 3-1 Definition of Function I/O(FI/O) pin of controller
INPUT
Pin
Parameter
Function
2
START
Execute program
3
HOLD
Pause program
4
STOP
Stop program
5
ENBL
Enable Function I/O
6
RSR1/PNS1
Robot service request 1 / program selection 1
7
RSR2/PNS2
Robot service request 2 / program selection 2
8
RSR3/PNS3
Robot service request 3 / program selection 3
9
RSR4/PNS4
Robot service request 4 / program selection 4
OUTPUT
Pin
Parameter
Function
10
RUN
Program running
11
HELD
Program pausing
12
FAULT
Controller failure
13
READY
Controller ready
14
ACK1/SNO1
RSR 1 feedback signal / selection program No. 1
25
ACK2/SNO2
RSR 2 feedback signal / selection program No. 2
26
ACK3/SNO3
RSR 3 feedback signal / selection program No. 3
27
ACK4/SNO4
RSR 4 feedback signal / selection program No. 4
Содержание RC4
Страница 1: ...www hiwin tw User Manual Robot Controller RC4 Series Original Instruction ...
Страница 64: ...C21UE102 2110 62 D SUB 44P INPUT NPN OUTPUT NPN ...
Страница 65: ...C21UE102 2110 63 D SUB 44P INPUT PNP OUTPUT PNP ...
Страница 77: ...C21UE102 2110 75 ...
Страница 79: ...C21UE102 2110 77 Figure 3 15 Digital output expansion model 32CH NPN configuration diagram ...
Страница 80: ...C21UE102 2110 78 Figure 3 16 Digital output expansion model 32CH PNP configuration diagram ...
Страница 82: ...C21UE102 2110 80 Figure 3 18 Digital output input expansion model 16 16CH NPN 1 configuration diagram ...
Страница 83: ...C21UE102 2110 81 Figure 3 19 Digital output input expansion model 16 16CH NPN 2 configuration diagram ...