7.1.4
Delivery Ambient Conditions
Environmental parameter
Unit
Value
Air temperature
(
°
C)
-15 ~ 55
Relative humidity
(%)
20 ~ 80
Rate of change of temperature
(
°
C/min)
0,5
Air pressure
kPa
70 ~ 106
Condensation
-
Not allowed
Formation of ice
-
Not allowed
Delivery the motor in an environment with good protection. (indoor/factory)
Note
Avoid exposing to direct sunlight or hear rays.
Away from electric magnetic interference source sites, such as welding, discharge
machine.
7.1.5
Safety Equipment to Be Provided by the Operator
Possible safety equipment/measures;
Personal protective equipment in accordance with regional regulations.
Zero-contact protective equipment.
Mechanical protective equipment.
7.2
Storage
Danger!
Danger from Strong Magnetic Fields
Strong magnetic fields around AC servo motor pose a health risk to persons with implants
(e.g. cardiac pacemakers) that are affected by magnetic fields.
Persons with implants that are affected by magnetic fields should maintain a safe distance
of at least 1 meter from AC servo motor systems.
Store the AC servo motor in its transport packaging.
Only store the AC servo motor in dry, frost-free areas with a corrosion-free atmosphere.
Clean and protect used AC servo motor before storage.
When storing AC servo motor, attach signs warning of magnetic fields.