OPERATOR'S STATION
1-78
Fuse Box
IMPORTANT: If a fuse blows, turn the key switch OFF.
After checking and correcting the cause of the trouble,
replace the fuse with a new one.
The slow blow fuses (1 and 2) function as a safety valve to
prevent excess current from flowing in the electrical system.
The fuse capacity varies depending on its corresponding
circuit. Be sure to replace the blown fuses only with the
specified ones.
When checking fuses, check the fuse box A, B and slow blow
fuses (1, 2 and 3) in this order.
Capacity of slow blow fuses
1- 100A×2
2- 65A×2
3- 45A×1
MNEC-01-047
Fuse Box A
Machine Front
Fuse Box B
1
3 2
MNSC-01-012