OPERATOR'S STATION
1-62
1
1
ON
5
6
Manual Regeneration Procedure
IMPORTANT:
Manual regeneration that is performed when the
aftertreatment device regeneration request is
displayed restores aftertreatment device function.
This is not a malfunction.
If the machine is continuously operated despite
the aftertreatment device regeneration request is
displayed, aftertreatment device alarm and engine
trouble alarm will be displayed, and the buzzer
sounds. Consult your authorized dealer for repairing
the aftertreatment device.
When the manual regeneration is needed, aftertreatment
device warning indicator (5) and service indicator (6) will light.
The manual regeneration is needed. Before starting manual
regeneration, be sure to check the following.
No person is present around the machine.
Keep flammable objects away from the muffler.
Fuel level indicator is not lit.
1. Park the machine in a safe place. Lower the front
attachment onto the ground.
2. Set the accelerator pedal and switches to the following
state.
Accelerator Pedal
: OFF
Forward/Reverse Lever
: N (Neutral)
Parking Brake Switch
: ON
Control Lever Lock Switch
: Lock ( )
Aftertreatment Device
Regeneration Inhibited Switch
: OFF
3. Turn aftertreatment device regeneration switch (1) in the
ON position.
MNDB-01-005
MPTC-01-019
MNSC-01-011
Содержание ZW 120-6
Страница 4: ......
Страница 10: ...MACHINE NUMBERS 2 MEMO ...
Страница 58: ...SAFETY SIGNS S 48 MEMO ...
Страница 156: ...BREAK IN 2 2 MEMO ...
Страница 206: ...OPERATING MACHINE 5 20 MEMO ...
Страница 218: ...TRANSPORTING 6 12 MEMO ...
Страница 331: ...MAINTENANCE 7 113 25 Cutting edge mounting bolt Bolt dia in 1 Quantity 7 M4GB 07 116 ...
Страница 344: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 4 MEMO ...
Страница 348: ...STORAGE 10 4 MEMO ...
Страница 354: ...TROUBLESHOOTING 11 6 MEMO ...
Страница 356: ...SPECIFICATIONS 12 2 MEMO ...
Страница 360: ...13 4 OPTIONAL ATTACHMENTS HYDRAULIC TYPE QUICK COUPLER OPERATION MEMO ...