Using Intelligent Input Terminals
Oper
ations
a
nd Moni
tor
ing
4–14
Wiring Diagram
Conventions
The input wiring diagrams in this chapter are examples only. Default and non-default input
terminal assignments are noted throughout; your particular assignments may be different. The
wiring diagrams show the –xFU/–xFR model default [P24]–[PLC] jumper position (U.S./Jpn
versions), as shown below on the left. The common (return) for inputs is [CM1] in this case.
The diagram on the right shows the default jumper position and example input wiring for –xFE
models (Europe version). For this case, the common (return) for inputs is [P24].
Be sure the
jumper position and return terminal used match your application wiring needs.
5
3
1
4
2
FW
TH
PLC
P24
CM1
5
3
1
4
2
FW
TH
PLC
P24
CM1
Default jumper
position [P24]–[PLC]
and wiring example
(used throughout this
chapter)
–xFU/–xFR models (U.S./Jpn versions):
–xFE models (Europe version):
Default jumper
position [PLC]–[CM1]
and wiring example
return
return
RV
FW
RV
FW
Содержание SJ700-004LFU2
Страница 2: ......
Страница 42: ......
Страница 162: ......
Страница 241: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 6 5 ...
Страница 248: ......
Страница 278: ......
Страница 279: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 6 A ...
Страница 359: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...
Страница 378: ......
Страница 390: ......