WARNING:
When parameter B_12, level of electronic thermal setting, is set to device
FLA rating (Full Load Ampere nameplate rating), the device provides solid state motor
overload protection at 115% of device FLA or equivalent. Parameter B_12, level of
electronic thermal setting, is a variable parameter.
NOTE:
For inverter models 005NFE, 011NFE, and 030HFE, the thermal value is less
than the rated amperes (is the same as models 004NFE, 007NFE, and 040HFE respec-
tively). Therefore, be sure to set the electronic thermal overload according to the actual
motor driven by the particular inverter.
“B” Function
Run
Mode
Edit
Defaults
Func.
Code
Name /
SRW Display
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)
Units
B_12 Level of electronic
thermal setting
Set a level between 50% and
120% for the rated inverter
current.
✘
Rated current for each
inverter model
*See note
A
E-THM LVL 03.00A
B212 Level of electronic
thermal setting, 2nd
motor
Set a level between 50% and
120% for the rated inverter
current.
✘
Rated current for each
inverter model
*See note
A
2E-THMLVL 03.00A
B_13 Electronic thermal
characteristic
Select from two curves, option
codes:
00... Reduced torque
01... Constant torque
✘
01
01
00
—
E-THM CHAR CRT
B213 Electronic thermal
characteristic, 2nd
motor
Select from two curves, option
codes:
00... Reduced torque
01... Constant torque
✘
01
01
00
—
2E-THMCHAR CRT
Содержание SJ100 Series
Страница 159: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 5 5 ...
Страница 186: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 194: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 B ...
Страница 204: ...CE EMC Installation Guidelines In This Appendix page CE EMC Installation Guidelines 2 Hitachi EMC Recommendations 6 C ...
Страница 207: ...CE EMC Installation Guidelines Appendix C C 4 L1 L2 L3 PE M 3 SJ100 inverter with footprint type filter ...
Страница 208: ...SJ100 Inverter Appendix C C 5 L1 L2 L3 PE SJ100 inverter with book type filter M 3 ...