On-screen message descriptions 9-5
(2) Faults that do not invoke ink stoppage
No.
Message
Meaning of message
Remedy
27
Print Data
Changeover
Error C
The print data change procedure was
incomplete.
●
Check the data entered
28
Print Data
Changeover
Error M
The print data change procedure was
incomplete.
●
Check the data entered
38
Free Layout
Printing Failure
The free layout printing was aborted while
the message was printing.
●
Delete some print items or
decrease the setting of the ink
drop use. ( 4.8.6)
40
External
Communication
Error nnn
The serial communication port had a data
error.
●
Note the error code and see
that no more error occure.
( Technical manual 5.7)
42
Ink Drop Charge
Too High
The charge sensor detects a high drop
charge.
●
Clean the gutter, deflection
electrode, and its
surroundings.
●
Adjust the excitation V-ref. to
make sure that the ink drops
are well made.
( Technical manual 6.11)
●
Adjust the ink pressure.
●
Check that the ink stream is
correctly retracted.
( Technical manual 6.10)
43
Barcode Short On
Numbers
The number of characters for the selected
barcode type is insufficient.
●
Configure the number of
( 4.8.5) characters for
barcode to appropriate value.
( Technical manual 9)
44 Shutdown Fault
The shutdown process failed.
●
Turn the printer power OFF by
main switch.
Contact your nearest local
distributor.
45 Count Overflow
The calculation result of the count
multiplier overflowed.
●
Change the count multiplier
setting.
46
Invalid Data
Change Timing
A print operation was requested while the
print data was being changed.
●
Change of either data change
or print start.
47
Invalid Count Data
Change Timing
A print operation was requested while the
print data was being changed.
●
Change of either data change
or print start.
48
Invalid Print Start
Timing
The print target detection signal for the next
target arrived during the data was being
changed.
●
Change of either data change
or print start.
49 Print Overlap Fault
The print target detecter signal for the next
target arrived during the print operation for
the current target.
●
Increase the spacing between
products.
●
If the target signal is
chattering, use sensor filter
setting. ( 4.14.1).
50
Print Head Cover
Open
The print head cover is open.
●
Remove the cover and then
hit the Clear key.
●
If a magnetic substance is
used to fix the cover,
it must be replaced with