Configuration 2.0 – Heat pump with heating buffer, valve control DHW with Legionella control
immersion heater and Electric heating backup
Configuration 2.0 – System Configuration (essential settings)
Parameter
Description
Menu
Conf
System Configuration 2.2
Reset menu
P301
DHW type 2 (pump)
03>03
P310
DHW Electric heater type 1 (Enable heater)
03>04
P309
DHW Anti legionella protection
04>03>07
System Configuration (other settings)
DHW loading times
01
P302 – P317
DHW set-point s and parameters
04>03>00-16
P001 – P002
Frost protection parameters
04>00>00-01
P003
Summer switch off
04>00>02
P801 – P810
Electric heater parameters
04>06>00-09
P009
Electric heater manual release on heat pump fault
03>06
Inputs to system controller – Configuration 2.0
U1
System supply temperature sensor
Extra Low voltage
U5
DHW temperature sensor
Extra Low voltage