![Hitachi RAC-E14H2 Скачать руководство пользователя страница 83](http://html.mh-extra.com/html/hitachi/rac-e14h2/rac-e14h2_service-manual_139795083.webp)
– 81 –
LD301 blinks 6 times.
The temperature at the
OH thermistor rises.
Is the thermistor circuit
normal?
Replace parts in the
thermistor circuit.
LD301 blinks 5 times.
Overload lower limit cut.
Replace the main P.W.B.
Check to see if the refrigerating cycle is defective.
Check the indoor unit for clogged heat exchanger or filter.
Check the outdoor unit for defective shielding.
LD301 blinks 4 times.
Failure of switching.
Is the 15V power supply
output normal?
(Power P.W.B. display)
Is the intelligent power
module (IPM) normal?
(Inverter section)
The intelligent power module
may be defective.
Replace the main P.W.B.
See “System Power
Module Diagnosis”.
With CN3 and CN4
disconnected, is the 15V
output between “15V” and
”15-0V” on the power
P.W.B.?
Replace the power P.W.B.
LD301 blinks 3 times.
Abnormal low speed.
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
08A395_RAS_35YH6_061-082_E
2008.01.31, 10:16
81
Содержание RAC-E14H2
Страница 17: ... 15 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAS E14H2A 08A395_RAS_35YH6_015 018_E 2008 03 04 17 01 15 ...
Страница 22: ...RAS E14H2A CIRCUIT DIAGRAM 20 08A395_RAS_35YH6_020 021_A2_E 2008 03 05 16 03 20 ...
Страница 25: ... 23 button 25 26 26 27 28 26 RAS E14H2A Silent Silent Silent 08A395_RAS_35YH6_023_A3_E 2008 03 10 15 38 23 ...
Страница 92: ... 90 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS E14H2A 08A395_RAS_35YH6_083 093_E 2008 03 10 15 50 90 ...
Страница 94: ...THE UPDATED PARTS LIST FOR THIS MODEL IS AVAILABLE ON ESTA 92 ...