Basic Heating Operation
Notes:
(1) Condition for entering into Hot Dashed mode. When fan set to “Hi” or “Auto mode” and i) Indoor temperature is lower than 18
°
C, and ii) outdoor temperature is lower than 10
°
C,
and iii) Temperature difference between indoor temperature and set temperature has a corresponding compressor speed (calculated value in Table 3) larger than WMAX.
(2) Hot Dashed will release when i) Room temperature has achieved the set tempe SFTDSW. ii) Thermo off.
(3) During Hot Dashed operation, thermo off temperature is set temperature (with shift value) +3
°
C. After thermo off, operation continue in Fuzzy control mode.
(4) Compressor minimum “ON” time and “OFF” time is 3 minutes.
(5) During normal heating mode, compressor maximum speed WMAX will maintain for 120 minutes if indoor temperature is higher than 18
°
C. No time limit constrain if outdoor temperature
is lower than 4
°
C.
(6) During Hotkeep or Defrost mode, indoor operation lamp will blink at interval of 0.5 seconds “ON” and 0.5 second “OFF”.
(7) When heating mode starts, it will enter into Hotkeep mode if indoor heat exchanger temperature is lower than YNEOF + 0.33
°
C.
(8) When fan is set to
comprossor speed will be limited to WSZMAX.
“Lo”, compressor speed will be limited to WBEMAX. When fan is set to "Med", compressor speed will be limited to WJKMAXG. When fan is set to “Silent”,
(9) In “Ultra-Lo” fan mode, if indoor temperature is lower than 18
°
C, indoor fan will stop. If indoor temperature is higher than 18
°
C + 0.33
°
C, fan will continue in “Ultra-Lo” mode.
During Hotkeep or Defrost mode, fan will continue in “Ultra-Lo” mode.
(10) During Hot Dashed, when room temperature reaches set tempe SFTDSW compressor speed is actual speed x DWNRATEW.
Table 3 Compressor speed
Temperature
difference
(with shift value)
1.66°C
2.00°C
2.33°C
2.66°C
3.00°C
3.33°C
3.66°C
4.00°C
Calculated
compressor speed
E14H2A
2500 min
–1
2900 min
–1
3300 min
–1
3700 min
–1
4100 min
–1
4500 min
–1
4900 min
–1
5200 min
–1
– 27 –
08A395_RAS_35YH6_025-028_A3_E
2008.03.06, 17:33
27
Содержание RAC-E14H2
Страница 17: ... 15 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAS E14H2A 08A395_RAS_35YH6_015 018_E 2008 03 04 17 01 15 ...
Страница 22: ...RAS E14H2A CIRCUIT DIAGRAM 20 08A395_RAS_35YH6_020 021_A2_E 2008 03 05 16 03 20 ...
Страница 25: ... 23 button 25 26 26 27 28 26 RAS E14H2A Silent Silent Silent 08A395_RAS_35YH6_023_A3_E 2008 03 10 15 38 23 ...
Страница 92: ... 90 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS E14H2A 08A395_RAS_35YH6_083 093_E 2008 03 10 15 50 90 ...
Страница 94: ...THE UPDATED PARTS LIST FOR THIS MODEL IS AVAILABLE ON ESTA 92 ...
Страница 95: ...HITACHI SM0027 RAS E14H2A RAC E14H2 ...