![Hitachi RAC-E14H2 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/hitachi/rac-e14h2/rac-e14h2_service-manual_139795011.webp)
–
9
–
08A395_RAS_35YH6_001-014_E
2008.02.15, 11:33
9
– 10 –
Press the (START/STOP) button. Cooling operation starts
with a beep. Press the button again to stop operation. The cooling
function does not start if the temperature setting is higher than
the current room temperature (even though the (OPERATION)
lamp lights).
The cooling function will start as soon as you set the temperature
below the current room temperature.
START
STOP
COOLING OPERATION
Use the device for cooling when the outdoor temperature is -10 to 42°C.
If humidity is very high (over 80%) indoors, some dew may form on the air outlet grille of the indoor
unit.
Press the FUNCTION selector so that the display indicates
(COOL).
1
Set the desired FAN SPEED with the (FAN SPEED) button
(the display indicates the setting).
(AUTO)
: The FAN SPEED is HI at first and varies to MED
automatically when the preset temperature has
been reached.
(HI)
: Economical as the room will become cool quickly.
(MED)
: Quiet.
(LOW)
: More quiet.
(SILENT) : Silent.
2
Set the desired room temperature with the TEMPERATURE
buttons (the display indicates the setting).
The temperature setting and the actual room temperature may
vary somewhat depending on conditions.
3
■
As the settings are stored in memory in the remote controller, you
only have to press the (START/STOP) button next time.
– 11 –
ENGLISH
Press the (START/STOP) button. Fan operation starts with a
beep.
Press the button again to stop operation.
START
STOP
FAN OPERATION
You can use the device simply as an air circulator. Use this function to dry the interior of the indoor unit
at the end of summer.
Press the FUNCTION selector so that the display indicates
(FAN).
1
Press the (FAN SPEED) button.
(HI)
: The strongest air blow.
(MED)
: Quiet.
(LOW)
: More quiet.
(SILENT) : Silent.
2
FAN SPEED (AUTO)
… When the AUTO fan speed mode is set in the cooling/heating operation:
For the heating operation
• The fan speed will automatically change according to the temperature of
discharged air.
• As room temperature reaches the preset temperature, a very light breeze
will blow.
• Operation starts in the “HI” mode to reach the preset temperature.
• As room temperature approaches the preset temperature, fan speed auto-
matically switches to “LOW”.
For the cooling operation
Содержание RAC-E14H2
Страница 17: ... 15 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAS E14H2A 08A395_RAS_35YH6_015 018_E 2008 03 04 17 01 15 ...
Страница 22: ...RAS E14H2A CIRCUIT DIAGRAM 20 08A395_RAS_35YH6_020 021_A2_E 2008 03 05 16 03 20 ...
Страница 25: ... 23 button 25 26 26 27 28 26 RAS E14H2A Silent Silent Silent 08A395_RAS_35YH6_023_A3_E 2008 03 10 15 38 23 ...
Страница 92: ... 90 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS E14H2A 08A395_RAS_35YH6_083 093_E 2008 03 10 15 50 90 ...
Страница 94: ...THE UPDATED PARTS LIST FOR THIS MODEL IS AVAILABLE ON ESTA 92 ...
Страница 95: ...HITACHI SM0027 RAS E14H2A RAC E14H2 ...