![Hitachi RAC-E14H2 Скачать руководство пользователя страница 61](http://html.mh-extra.com/html/hitachi/rac-e14h2/rac-e14h2_service-manual_139795061.webp)
– 59 –
AUTO FRESH DEFROSTING
AUTO OPERATION
NICE TEMPERATURE RESERVATION
INFRARED REMOTE CONTROL
After the ON/OFF button is pressed
to stop heating, the outdoor unit is
still working with the OPERATION
lamp lighting.
Fan speed does not change when
fan speed selector is changed
during auto operation.
When on-timer has been
programmed, operation starts before
the preset time has been reached.
Does Nice temperature reservation
function operate during dehumidifying?
Even if the same time is preset,
the operation start time varies.
Timer cannot be set.
The current time display
disappears soon.
The timer has been programmed,
but the preset time disappears.
Auto Fresh Defrosting is carried out : the
system checks the outdoor heat exchanger
and defrosts it as necessary before stopping
operation.
At this point fan speed is automatic.
This is because Nice temperature reservation
function is operating. This function starts
operation earlier so the preset temperature is
reached at the preset time. Operation may start
maximum 60 minutes before the preset time.
It does not work. It works only during cooling
and heating.
This is because Nice temperature reservation
function is operating. The start time varies
according to the load of room. Since load varies
greatly during heating, the operation start time is
corrected, so it will vary each day.
Has the clock been set? Timer cannot be set
unless the clock has been set.
The current time disappears
in approx. 10 seconds. The
time set display has priority.
Is the current time past the preset time?
When the preset time reaches the current
time, it disappears.
When the current time is
set the display flashes for
approx. 3 minutes.
Q8
A8
Q9
A9
Q10
A10
Q11
A11
A12
Q13
A13
Q14
A14
Q15
A15
Q12
Содержание RAC-E14H2
Страница 17: ... 15 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAS E14H2A 08A395_RAS_35YH6_015 018_E 2008 03 04 17 01 15 ...
Страница 22: ...RAS E14H2A CIRCUIT DIAGRAM 20 08A395_RAS_35YH6_020 021_A2_E 2008 03 05 16 03 20 ...
Страница 25: ... 23 button 25 26 26 27 28 26 RAS E14H2A Silent Silent Silent 08A395_RAS_35YH6_023_A3_E 2008 03 10 15 38 23 ...
Страница 92: ... 90 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS E14H2A 08A395_RAS_35YH6_083 093_E 2008 03 10 15 50 90 ...
Страница 94: ...THE UPDATED PARTS LIST FOR THIS MODEL IS AVAILABLE ON ESTA 92 ...
Страница 95: ...HITACHI SM0027 RAS E14H2A RAC E14H2 ...