– 74 –
●
DC 260-360V is input to system power module and system power module switches power supply current
according to rotation position of magnet rotor. The switching order is as shown in Fig. 3-2.
E
F
U
V
V
W
Upper arm
transistor
Lower arm
transistor
Time
+
+
T
+
+
T
U –
V –
W –
U transistor chopped
U transistor ON
ON
Voltage at
Upper arm transistor
Current at
Chopping period
260V-360V
A
+
-
B
At point E: U+ is ON, V– is ON (circuit in Fig. 3-1)
At point F: U+ is chopped (OFF), V– is ON (circuit in Fig. 3-4)
[
]
●
Upper arm transistor is controlled to ON/OFF by 3.3kHz chopper signal. Rotation speed of the compress
is proportional to duty ratio (ON time/ ON time + OFF time) of this chopper signal.
●
Time T in Fig. 3-2 shows the switching period, and relation with rotation speed (N) of the compressor is
shown by formula below;
Fig. 3-2 Switching order of power module
N = 60/2 X 1/T
●
Fig. 3-3 shows voltage waveform at each point shown in Figs. 3-1 and 3-4. First half of upper arm is
chopper, second half is ON, and first half of lower arm is chopper, second half is ON.
Fig. 3-3 Voltage waveform at each point
●
When power is supplied U+
[
U–, because of that U+ is chopped, current flows as shown below;
(1)
When U+ transistor is ON: U+ transistor
[
U coil
[
V coil
[
V– transistor
[
DC current detection
resistor
[
Point (Fig. 3-1)
(2)
When U+ transistor is OFF: (by inductance of motor coil) U coil
[
V coil
[
V– transistor
[
Return
diode
[
Point (Fig. 3-4)
A
B
B
Содержание RAC-65NH5
Страница 36: ...CIRCUIT DIAGRAM 37 ...
Страница 37: ...CIRCUIT DIAGRAM MODEL RAC 65NH5 39 ...
Страница 87: ... 99 SELF DIAGNOSIS LIGHTING MODE ...
Страница 89: ... 101 2 Outdoor unit does not operate but receives remote infrared signal ...
Страница 91: ... 103 6 Check the main P W B power circuit ...
Страница 92: ... 104 CHECKING THE REMOTE CONTROLLER ...
Страница 97: ... 109 ...
Страница 103: ... 115 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAK 65NH5 2 1 9 7 8 6 19 20 3 11 4 5 10 13 15 14 17 16 12 22 26 18 27 ...