![Hitachi HUS VM Скачать руководство пользователя страница 423](http://html.mh-extra.com/html/hitachi/hus-vm/hus-vm_user-and-reference-manual_145969423.webp)
Table 9-49 SSB codes returned by raidcom get snapshot
raidcom get snapshot
Error message
Executing/
Async
Error code
Description
SSB1
SSB2
CMDRJE
Executing
2EC5
FEEC
An internal error occurred. Call Hitachi Data
Systems customer support.
Table 9-50 SSB codes returned by raidcom delete snapshot
raidcom delete snapshot
Error message
Executing/
Async
Error code
Description
SSB1
SSB2
CMDRJE
Executing
2E00
0000
The LDEV number is out of settable range.
CMDRJE
Executing
2E00
000B
The MU number exceeds the maximum.
CMDRJE
Executing
2E00
0028
The command ends abnormally because the
volume whose LDEV number is out of range is
specified as the P-VOL of a Thin Image pair or a
Copy-on-Write Snapshot pair.
CMDRJE
Executing
2E10
0033
The command ends abnormally because the
ShadowImage reserved volume is specified as the
P-VOL of a Thin Image pair or a Copy-on-Write
Snapshot pair.
CMDRJE
Executing
2E10
0034
The command ends abnormally because the
Volume Migration source volume is specified as the
P-VOL of a Thin Image pair or a Copy-on-Write
Snapshot pair.
CMDRJE
Executing
2E10
0035
The command ends abnormally because the
Volume Migration target volume is specified as the
P-VOL of a Thin Image pair or a Copy-on-Write
Snapshot pair.
CMDRJE
Executing
2E10
0036
The command ends abnormally because the
Volume Migration reserved volume is specified as
the P-VOL of a Thin Image pair or a Copy-on-Write
Snapshot pair.
CMDRJE
Executing
2E10
0049
The command ends abnormally because the
ShadowImage pair is being resynchronized when
the volume is shared between the P-VOL of a Thin
Image/Copy-on-Write Snapshot pair and the P-VOL
of a ShadowImage pair.
CMDRJE
Executing
2E10
004A
The command ends abnormally because the
ShadowImage pair status is other than PSUS when
the volume is shared between P-VOL of a Thin
Image/Copy-on-Write Snapshot pair and the S-VOL
of a ShadowImage pair.
CMDRJE
Executing
2E10
004D
A Snapshot data cannot be obtained because the
TrueCopy asynchronous pair status is other than
Troubleshooting
9-99
Command Control Interface User and Reference Guide
Содержание HUS VM
Страница 10: ...x Command Control Interface User and Reference Guide ...
Страница 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Страница 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Страница 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Страница 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Страница 277: ... 1 UR 2x2 Data replication operations with CCI 6 53 Command Control Interface User and Reference Guide ...
Страница 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Страница 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Страница 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Страница 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Страница 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Страница 529: ...Command Control Interface User and Reference Guide ...