![Hitachi HUS VM Скачать руководство пользователя страница 400](http://html.mh-extra.com/html/hitachi/hus-vm/hus-vm_user-and-reference-manual_145969400.webp)
raidcom modify pool
Error message
Executing/
Async
Error code
Description
SSB1
SSB2
Get Command
Status
Async
2E21
8103
The operation cannot be performed because of the
insufficient capacity of shared memory.
Get Command
Status
Async
2E21
810A
The shared memory is not installed.
Get Command
Status
Async
2E21
9000
The program product is not installed.
CMDRJE
Executing
2E21
9014
Data Retention Utility program product is not
installed.
CMDRJE
Get Command
Status
Executing/
Async
2E22
0001
The specified LDEV is already defined.
Get Command
Status
Async
2E23
0001
The number exceeds the maximum number of
LDEVs that can be created in the current system
configuration.
CMDRJE
Get Command
Status
Executing/
Async
2E23
0008
The number of specified deduplication system data
volumes exceeds the maximum limit.
CMDRJE
Executing
2E23
7201
The specified SSID number exceeds the maximum
limit.
Get Command
Status
Async
2E30
0020
The specified SSID is already used in the another
CU.
Get Command
Status
Async
2E30
0021
The SSID is already allocated to the CU.
Get Command
Status
Async
2E30
0025
The specified volume is used as an alias device in
Compatible PAV.
Get Command
Status
Async
2E30
0026
An LDEV of another emulation type is allocated in
the range where the number is divided into each
32 LDEVs.
CMDRJE
Executing
2E30
006E
The Dynamic Tiering or active flash operation
cannot be performed to the pool because the
specified pool contains the external volumes whose
cache mode is invalid.
CMDRJE
Get Command
Status
Executing/
Async
2E30
0071
A pool volume cannot be operated because the
LDEV of the resource group different from the
resource group of the pool volume belonging to the
specified pool is specified.
Get Command
Status
Async
2E30
009A
The page reservation cannot be set on the
specified LDEV with the specified operation.
Get Command
Status
Async
2E30
4119
The operation cannot be performed because the
number of V-VOLs that can be created in the
system exceeds the maximum number.
CMDRJE
Executing
2E30
6000
The threshold value 1 is out of range.
9-76
Troubleshooting
Command Control Interface User and Reference Guide
Содержание HUS VM
Страница 10: ...x Command Control Interface User and Reference Guide ...
Страница 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Страница 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Страница 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Страница 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Страница 277: ... 1 UR 2x2 Data replication operations with CCI 6 53 Command Control Interface User and Reference Guide ...
Страница 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Страница 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Страница 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Страница 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Страница 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Страница 529: ...Command Control Interface User and Reference Guide ...