time. You can also set the same upper limit value for all host bus adapters in
an SPM group at the same time.
Examples of setting the SPM group:
Set the SPM name (ORA_NODE0_CTL_0) for the SPM gropup name
(WWN_GRP_LINUX0).
# raidcom add spm_group -port CL4-E -spm_group WWN_GRP_LINUX0
ORA_NODE0_CTL_0
Set the WWN (210000e08b039c15) for the SPM gropup name
(WWN_GRP_LINUX1).
# raidcom add spm_group -port CL4-E -spm_group
WWN_GRP_LINUX1 -hba_wwn 210000e0,8b039c15
SPM group names are managed uniquely in the entire system.
Obtaining monitoring information of the prioritized WWN and the
non-prioritized WWN
You can use the monitoring function to check whether the performance of the
prioritized WWN can be secured by setting the upper limit. Example of
acquiring the monitoring information:
Acquires the monitoring information by specifying the WWN
(210000e08b039c15).
# raidcom monitor spm_wwn -hba_wwn 210000e0,8b039c15
PORT SPM_MD IOps KBps Serial#
CL4-E WWN 5000 5000000 63528
Stopping performance control of server by using SPM function
To stop controlling the performance of the server by using the SPM function,
delete the SPM name from the SPM targets.
Example of deleting from the SPM targets:
Delete the SPM name ("ORA_NODE0_CTL_0") from the SPM targets.
# raidcom delete spm_wwn -port CL4-E -spm_name ORA_NODE0_CTL_0
Cautions about using Server Priority Manager
The following table describes the cautions about using Server Priority
Manager.
Caution
Description
Exclusive access
control with
Storage
Navigator
Server Priority Manager settings are exclusive for CCI operations and
Storage Navigator operations:
•
If you set Server Priority Manager using CCI, you cannot set
Server Priority Manager from Storage Navigator. You need to
delete all Server Priority Manager settings made using CCI, and
then use Server Priority Manager on Storage Navigator to make
the Server Priority Manager settings.
Provisioning operations with CCI
5-63
Command Control Interface User and Reference Guide
Содержание HUS VM
Страница 10: ...x Command Control Interface User and Reference Guide ...
Страница 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Страница 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Страница 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Страница 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Страница 277: ... 1 UR 2x2 Data replication operations with CCI 6 53 Command Control Interface User and Reference Guide ...
Страница 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Страница 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Страница 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Страница 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Страница 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Страница 529: ...Command Control Interface User and Reference Guide ...