![Hitachi HUS VM Скачать руководство пользователя страница 413](http://html.mh-extra.com/html/hitachi/hus-vm/hus-vm_user-and-reference-manual_145969413.webp)
raidcom add snapshot
Error message
Executing/
Async
Error code
Description
SSB1
SSB2
CMDRJE
Executing
2E10
8102
A pair cannot be created because there is not
enough free shared memory space.
CMDRJE
Executing
2E10
9701
The command ends abnormally because the pair is
in the state of unacceptable the command.
CMDRJE
Executing
2E10
9705
A Thin Image pair or a Copy-on-Write Snapshot
pair cannot be created because the number of Thin
Image pairs or Copy-on-Write Snapshot pairs has
already reached the maximum.
CMDRJE
Executing
2E10
9706
A Thin Image pair cannot be created because the
maximum number of Snapshot IDs (MU numbers)
has already been in use for the specified P-VOL.
CMDRJE
Executing
2E10
9707
A Thin Image pair cannot be created because the
maximum number of Snapshot groups has already
been defined, or the maximum number of Thin
Image pairs has already been defined in the
specified Snapshot group.
CMDRJE
Executing
2E10
9708
A Thin Image pair cannot be created because the
DP pool is being initialized.
CMDRJE
Executing
2E10
970D
The pair cannot be created because the number of
pair layers in the cascade configuration exceeds
the maximum number.
CMDRJE
Executing
2E10
970E
The pair cannot be created because the number of
clone attribute pair layers exceeds the maximum
number.
CMDRJE
Executing
2E10
970F
When the pair status is other than PAIR or PSUS,
you cannot create a pair by specifying the S-VOL of
a Thin Image pair.
CMDRJE
Executing
2E10
9712
Thin Image pairs that can be cascaded or cloned
and Thin Image pairs that cannot be cascaded or
cloned cannot be contained in a snapshot tree.
CMDRJE
Executing
2E10
9713
The operation cannot be performed because the
snapshot tree is being deleted.
CMDRJE
Executing
2E10
9800
An error occurred at the operation of Thin Image
due to one of the following reasons:
•
The LDEV number specified for the P-VOL or
the S-VOL is incorrect.
•
The LDEV specified as the P-VOL or the S-VOL
is not paired.
•
The pair of the specified P-VOL or the S-VOL is
not ready to perform the specified operation.
•
The specified Snapshot ID (MU number) is
wrong.
•
The specified Snapshot ID (MU number) is
already used.
Troubleshooting
9-89
Command Control Interface User and Reference Guide
Содержание HUS VM
Страница 10: ...x Command Control Interface User and Reference Guide ...
Страница 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Страница 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Страница 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Страница 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Страница 277: ... 1 UR 2x2 Data replication operations with CCI 6 53 Command Control Interface User and Reference Guide ...
Страница 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Страница 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Страница 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Страница 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Страница 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Страница 529: ...Command Control Interface User and Reference Guide ...