6005 8831
The specified R-VOL is already used as a
CruiseControl Reserve VOL.
Check the status of the specified R-VOL (S-VOL)
from HOST or SVP.
I 4
6005 8832
Please wait a few minutes and retry the Add Pair
(Paircreate) / Resume Pair (Pairresync) operation.
Please check the status of the specified M-VOL
(P-VOL), and then retry the Add Pair (Paircreate)
/ Resume Pair (Pairresync) operation in a few
minutes.
I 4
6005 8833
Please wait a few minutes and retry the Add Pair
(Paircreate) / Resume Pair (Pairresync) operation.
Please check the status of the specified R-VOL
(S-VOL), and then retry the Add Pair (Paircreate)
/ Resume Pair (Pairresync) operation in a few
minutes.
I 4
6005 8834
The Add Pair (Paircreate) operation failed because
you tried to create volume pairs which exceeded the
licensed capacity.
Refer to the license key and confirm the licensed
capacity of the volumes. If you need to create
more pairs, purchase a license key that allows
you to use a larger capacity.
E 4
6005 8835
The Add Pair (Paircreate) operation failed because
you tried to create volume pairs which exceeded the
licensed capacity of the RCU side.
Refer to the license key of the RCU side, and
confirm the licensed capacity of the volumes. If
you need to create more pairs, purchase a
license key that allows you to use a larger
capacity.
E 4
6005 8836
No additional volume pairs waiting for copy.
Please check the pair status and retry.
I
4
6005 8837
An internal error occurred.
An internal error has occurred. Please call the
Hitachi Data Systems Support Center.
E 4
6005 8838
Specified volume is not part of a Remote Copy pair. The specified volume is not part of a TrueCopy
pair. Please check the volume.
I 4
6005 8839
Invalid RCU serial number, SSID, Link Address or
Controller ID.
Check the serial number, SSID and link address
of the RCU, and set the correct value. Then retry
the operation. If the same error occurs, contact
the Hitachi Data Systems Support Center.
E 4
6005 8840
Suspend(Pairsplit-r) operation is not valid for R-VOL. Suspend mode is not valid for the R-VOL. Check
the volume and retry.
I 4
6005 8841
Invalid R-VOL.
Please check the R-VOL status.
E
4
6005 8842
R-VOL status change failed after M-VOL status
change. Confirm R-VOL status.
Confirm the R-VOL status.
E
4
6005 8843
Suspend(Pairsplit-r) operation failed because
specified volume or other volume in the same group is
not in permissible status.
The operation failed, because of one of the
following reasons:
1. The specified volume is simplex.
2. There is no duplex or duplex-pending volume
in the group.
3. Either the specified volume or another volume
in the same group are suspended. Verify the
status, and retry the operation.
I 4
6005 8844
Suspend(Pairsplit-r) operation failed because
specified volume or other volume in the same group is
in status transition.
The operation failed, because of one of the
following reasons:
1. The specified volume or another volume in the
same group are deleting.
2. The specified volume or another volume in the
same group are suspending. Wait for the change
in status to be completed, then retry the
operation.
I 4
6005 8845
Preset Suspension is effective in the CT Group.
Cancel the preset suspension in the C/T group,
then retry the operation.