46
Chapter 1 Error Codes
6005 8804
Copy mode cannot be changed.
The resume pair operation failed. The volume
and the copy mode must be either both
asynchronous or both synchronous. Verify that
the status of the volume and the copy mode
match, then retry the operation.
I 4
6005 8805
CT Group is not active in the RCU.
The resume pair operation failed, because there
is no R-VOL in the C/T Group. Verify the status
of the C/T group in the MCU/RCU. If an M-VOL
exists, delete it and retry the add pair operation.
I 4
6005 8806
CT Group Option cannot be changed unless deleting
or suspending all asynchronous pairs in the group.
If you want to change the C/T group option (timer
type or time out), either delete all asynchronous
pairs in the group, or verify the status of the RCU
C/T Group option and set the same option as the
MCU.
I 4
6005 8807
Too many MCUs in this CT Group.
The add pair operation failed because there are
too many MCUs in this C/T group. If the timer
type is System, then 4 MCUs have already been
added. If the timer type is local or none, then 1
MCU has already been added.
I 4
6005 8808
Please retry. Add Pair(Paircreate)/Resume
Pair(Pairresync) operation after waiting a few minutes.
The add/resume pair operation failed, because
the either the specified volume or another
volume in the same group is being changed to
simplex or suspend status. Retry the operation
after the status change is completed.
I 4
6005 8809
Please wait. Retry Add Pair(Paircreate)/Resume
Pair(Pairresync) operation in a few minutes.
Add/resume pair operation failed. The specified
volume or another volume in the same group
being changed to simplex/suspend status in
RCU. A few minutes later, please renew and
check the TrueCopy screen and if specified
volume is in a permissible status please retry the
operation.
I 4
6005 8810 TrueCopy
–
S/390
®
Asynchronous function is not
installed in specified RCU.
Install TrueCopy Asynchronous in the RCU and
retry the operation.
I 4
6005 8811
This version does not support multiple CT Groups in
the RCU.
This microcode version does not support multiple
C/T groups in the RCU. Verify the status and
retry.
I 4
6005 8812
This version does not support combining TrueCopy –
S/390
®
Asynchronous pairs and Synchronous pairs in
the DKC subsystems(s).
The add pair operation failed. This version does
not support intermix of TrueCopy Asynchronous
pairs and Synchronous pairs in the same DKC.
Refresh the screen and confirm the Copy Mode
in the MCU and RCU.
I 4
6005 8813
Specified M-VOL is a ShadowImage-
S/390
®
/ShadowImage volume. This version does not
support it.
This microcode version does not support
ShadowImage, and the specified M-VOL is a
ShadowImage volume. Verify the status of the M-
VOL and retry.
I 4
6005 8814
Specified R-VOL is a ShadowImage-
S/390
®
/ShadowImage volume. This version does not
support it.
This microcode version does not support
ShadowImage, and the specified R-VOL is a
ShadowImage volume. Verify the status of the
R-VOL and retry.
I 4
6005 8815
TrueCopy Asynchronous function is not installed in
specified RCU.
Install the TrueCopy Asynchronous function in
the RCU, then retry the operation.
I 4