Hitachi Lightning 9900™ V Series Remote Console Error Codes
41
6005 8730 Invalid
Logical Addresses are specified.
1. If you are adding RCUs, specify the same
logical address.
2. If you are editing paths, specify the same
logical address as the existing paths. (Refer to
the Edit Path Screen.)
I 4
6005 8731
The existing logical addresses are not equal.
The logical addresses of all existing paths are
not the same. Delete the RCU, then re-add it,
using the same logical address as other existing
paths.
I 4
6005 8732
Too many SSIDs(Only Four SSIDs are allowed).
The maximum number of SSIDs (four) has been
entered. Verify that the SSIDs are valid, delete
one or more, and then retry the operation.
E 4
6005 8733
The Fibre-Remote Copy function is not installed in the
specified MCU.
Please install the program product key in the
MCU.
I 4
6005 8734
The Fibre-Remote Copy function is not installed in the
specified RCU.
Please install the program product key in the
RCU.
I 4
6005 8735
Invalid RCU serial number, SSID, Link Address or
Controller ID.
Check the serial number, SSID and link address
of the RCU, and set the correct value. Then retry
the operation. If the same error occurs, contact
the Hitachi Data Systems Support Center.
E 4
6005 8736 The
specified RCU or SSID contains some Remote
Copy volume pairs.
Invalid serial number or SSID for this operation.
Either the RCU is not a proper machine type for
TrueCopy, or the RCU's controller is not the
proper type for data migration. Check the serial
number and SSID of the RCU, and set the
correct value.
I 4
6005 8737
An internal error occurred.
An internal error has occurred. Please call the
Hitachi Data Systems Support Center.
E 4
6005 8738
Remote Copy is not supported under the MCU
Controller emulation type.
The emulation type of the MCU does not support
TrueCopy. If you want to use TrueCopy, please
call the Hitachi Data Systems Support Center.
I 4
6005 8739
NVS status of MCU is not active.
The MCU NVS status specified by the host is not
active. Set the NVS to “on” for the MCU, using
any attached host, then retry the operation.
I 4
6005 8740
NVS status of RCU is not active.
The RCU NVS status specified by the host is not
active. Use any attached host to set the NVS to
“on” for the MCU, then retry the operation.
I 4
6005 8741
The logical paths between the MCU and RCU are not
established.
Check the path status between the MCU and the
RCU.
I 4
6005 8742 Pinned
track(s)
exists on the M-VOL.
Check the status of the M-VOL tracks, and clear
the pinned tracks.
W 4
6005 8743
Pinned track(s) exists on the R-VOL.
Check the status of the R-VOL tracks, and clear
the pinned tracks.
W 4