K6610007
Rev.5
02.14.’03
- 62 -
6.3.2.8.11 SMART Execute Off-line Immediate [B0h, Sub D4h]
Task
File
Registers
7 6 5 4 3 2 1 0
Command B0h
Cylinder High
C2h
Cylinder Low
4Fh
Device/Head -
X -
DRV XX
Sector Number
XX
Sector Count
XX
Features
D4h
DRV : Device selection bit
0 : DRV0
1:DRV1
This command causes the device to immediately initiate the optional set of off-line data collection activities
that collect attribute data in an off-line mode and then save this data to the device, or execute a self-
diagnostic test routine in either captive or off-line mode.
Table 6.11
SMART EXECUTE OFF-LINE IMMEDIATE Sector Number register values
Value
Description of subcommand to be executed
0
Execute SMART off-line routine immediately in off-line mode
1
Execute SMART Short self-test routine immediately in off-line mode
2
Execute SMART Extended self-test routine immediately in off-line mode
3 Reserved
4
Execute SMART Selective self-test routine immediately in off-line mode
5 - 63
Reserved
64 - 125
Reserved (Vendor specific)
126
Abort off-line mode off-line routine (Vendor specific)
127
Abort off-line mode self-test routine
128 Reserved
129
Execute SMART Short self-test routine immediately in captive mode
130
Execute SMART Extended self-test routine immediately in captive mode
131 Reserved
132
Execute SMART Selective self-test routine immediately in captive mode
133- 191
Reserved
192 - 255
Reserved (Vendor Specific)
(1) Off-line mode
The following describes the protocol for executing a SMART EXECUTE OFF-LINE IMMEDIATE
subcommand routine (including a self-test routine) in the off-line mode.
a) The device executes command completion before executing the subcommand routine.
b) After clearing BSY to zero and setting DRDY to one after receiving the command, the device does not
set BSY nor clears DRDY during execution of the subcommand routine.