9-6. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance and dielectric strength.
Insulation resistance: 7 M
Ω
or more with DC 500 V megohm tester
Dielectric strength:
AC 4,000 V/1 minute, with no abnormalities 220 V --- 240 V (and 110 V for U.K. products)
AC 2,500 V/1 minute, with no abnormalities 110 V --- 127 V (except for U.K. products)
9-7. No-load Current Values
After no-load operation for 30 minutes, the no-load current value should be as follows:
Voltage (V)
Current (A) (max.)
6.4
110
Mounting diagram for products with noise suppressor
5.9
120
3.2
220
3.1
230
2.9
240
Lead wires of switch and cord
Control circuit ass'y
(including noise suppressor)
Case (A)
Housing
Lead wire of noise
suppressor