32
CP-X444(C11XMB)/CP-X440(C11XM25)
Wiring diagram 3
Wiring when attaching the power supply block
When attaching the power supply block
(1) Connect the CNLC
(2) Be cautious of pinching the wires when attaching
the power supply (in particular, the CNLC)
(3) Connect the AC lead
(4) Attach the CNFG
Important
Make
sure
secure
the
CNPW1,
TSW,
and
#6800
cables
by
passing
then
through
the
clamp of the ballast holder.
Protect the CNLC from the sharp edge of
power supply block by covering with tape.
Connect the cable end that is closest to
ZTP2 to Limit switch board.
to Main board
to Limit switch board
aprx. 5mm
CNLC
ZTP2
Power supply block
CN105
Filter
board
#6800
CNBAR
TSW
CNPW1
Limit
switch
board
ZTP2
CNLC
CNFG
I/O metal
Bottom case
CNFG
Screw
one
end
of
the
CNFG
to the I/O metal , in the posi-
tion indicated by the diagram.
AC
lead
Earth
lead
When connecting the AC
lead
connector
to
the
CN105,
make
sure
it
locks in place completely.