Hitachi High-performance NAS Platform Components
Warning:
There are two versions of the FSX2034 module; FSX2034-0 and
FSX2034-1. The component difference has no effect on module/server performance,
and there are no external differences between the versions, with the exception of
labels. If your FSX is an FSX2034-1, the minimum supported software revision is SU
5.2, and you must configure that module with the second stage loader (SSLoader)
version from SU 6.0 (or above). Note, however, that the NIM, FSA, and SIM modules
in the server can run older versions of SSLoader. Refer to the Hitachi High-
performance NAS Platform System Installation Guide for instructions on using
SSLoader. Contact Hitachi Data Systems Technical Resource Center (TRC) for more
information, or if you have questions about SSLoader versions or installation.
FSB302x
The FSB module has only one LED which is the Transaction Log Status LED (Green/
Amber). This LED indicates the status of a battery backed NVRAM.
FSB303x
Table 13: Transaction Log Status LED (Green/Amber)
State
Meaning
Off
Transaction logging disabled, or battery exhausted.
Green
Transaction log active (locally or with remote High-performance NAS Platform).
Amber
Battery condition fault.
Green Flash
(1 Hz)
Recoverable transaction log held in NVRAM.
Amber Flash
(1 Hz)
There is a recoverable transaction log in NVRAM (as per green flash) and the
battery is low.