-Slot the cooker top into the unit and position.
-Position the cooker top in the recess and secure by means of
the brackets as shown in fig.12 (for 3 or 4 cm thick work top).
GAS SECTION
TYPES OF GASES
The gases normally used may be grouped, in view of their features in three families:
-L.P.G.(in cylinders) G30 28-30mbar
-NATURAL GAS(methane) G20 20mbar
IMPORTANT: By default, the built-in gas hob comes with nozzles suitable for LPG
The appliance should be installed, regulated and adapted to function with other types of gas by
a
QUALIFIED INSTALLATION TECHNICIAN.
INSTALLATION
The appliance is predisposed and adjusted to operate with the gas indicated on the
specifications plate applied onto the appliance.
If the appliance must be operated with a gas different than that indicated on the plate, it is
necessary to execute the following operations:
gas connection
replacement of the injectors
regulating of the minimum
8