Installation RSPE 30/32/35/37
Release 12 10/2015
55
Climatic
conditions
during storage
Ambient air temperature
b
−
40 °F ... +185 °F (
−
40 °C ... +85 °C)
Humidity
5 % ... 95 %
(non-condensing)
Air pressure
minimum 700 hPa (+9842 ft; +3000 m)
maximum 1060 hPa (
−
1312 ft;
−
400 m)
Signal contact
See “Requirements for connecting electrical wires” on page 6.
Switching current
max. 1 A
Switching voltage
max. 60 V DC
max. 30 V AC
under UL conditions: max. 30 V DC, resistive
load
Pollution degree
2
Protection
classes
Laser protection
Class 1 in compliance with IEC 60825-1
Degree of protection
IP20
a. Operation with power supply with characteristic value PP without using PoE or PoE+ in the
range 24 VDC (19 VDC) ... 48 VDC (60 VDC) is not covered by UL approvals.
b. Reduction of the maximum permitted ambient air temperature under specific conditions
c. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device
d. Hirschmann recommends to use SFP transceivers with the "EEC" extension.
e. Use only SFP transceivers with the “EEC” extension, otherwise the standard temperature
range applies.
f.
when equipped with maximum 8 SFP transceivers; if a higher number is connected, the
following maximum values apply for the ambient air temperature:
9 to 12 transceivers: +149 °F (+65 °C); more than 12 transceivers: +140 °F (+60 °C)
g. when equipped with maximum 8 SFP transceivers; if a higher number is connected, the
following maximum values apply for the ambient air temperature:
9 to 12 transceivers: +176 °F (+80 °C); more than 12 transceivers: +167 F (+75 °C)