![Hirschmann RSPE 30 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/hirschmann/rspe-30/rspe-30_user-manual_2138134012.webp)
12
Installation RSPE 30/32/35/37
Release 12 10/2015
IECEx – Certification Scheme for Explosive Atmospheres
For RSPE devices labeled with an IECEx certificate number, the following
applies:
List of standards:
IEC 60079-0:2011+Cor.2012+Cor.2013
IEC 60079-15:2010
The device is suitable for use in an area with a degree of soiling of 2
as per IEC 60664-1.
Make sure that the device has the following label:
Ex nA IIC T4 Gc
IECEx DEK 15.0013X
for RSPE types
Environmental class and temperature code for RSPE types:
T4: 0 °C
≤
Ta
≤
+60 °C for “S“ types
or
T4:
−
40 °C
≤
Ta
≤
+70 °C for “T“ or “E“ types
The modules shall be installed in a suitable enclosure in accordance
with IEC 60079-15 providing a degree of protection of at least IP54
according to IEC 60529, taking into account the environmental
conditions under which the equipment will be used.
When the temperature under rated conditions exceeds 70 °C at the
cable or conduit entry point, or 80 °C at the branching point of the
conductors, the temperature specification of the selected cable and
cable entries shall be in compliance with the actual measured
temperature values.
Provisions shall be made to prevent the rated voltage from being
exceeded by transient disturbances of more than 119 V.
Connectors shall be connected or disconnected exclusively in dead-
voltage state.
The USB port shall remain disconnected.
CE marking
The labeled devices comply with the regulations contained in the
following European directive(s):