1. GENERAL INFORMATION 

 

The PAT Length-Angle-Radius-Load Indicator System EI65 has been designed to provide the crane 
operator with the essential information required to enable the machine to be used within its design 
parameters. The EI65 System indicates the length and angle of the boom, tip height, working radius 
and the total calculated weight being lifted by the crane. 
 
Using various sensing devices, the EI65 System warns the crane operator of certain approaching 
hazardous conditions, which could occur during the operation of the crane.  
 
The purpose of this Operator’s Manual is to provide information to help the crane operator operate, 
maintain and troubleshoot the PAT System. 
 
The manual contains the system description, operating, and calibration information. 
 
 

 

 

Always refer to operational instructions and load charts provided by the crane manufacturer 

for specific crane operation and load limits. 

 

2. WARNINGS 

 

  The EI65 is an operational aid that warns a crane operator of certain approaching hazardous 

conditions, which could cause damage to equipment and personnel. 

  The device is not, and shall not be, a substitute for good operator judgment, experience and use of 

accepted safe crane operating procedures. 

  The responsibility for the safe operation of the crane shall remain with the crane operator who shall 

ensure that all warnings and instructions supplied are fully understood and observed. 

  Prior to operating the crane, the operator must carefully and thoroughly read and understand the 

information in this manual to ensure that he knows the operation and limitations of the indicator 
and crane. 

  Proper functioning is dependent upon proper daily inspection and observations of the operating 

instructions set forth in this manual. 

 

Содержание PAT EI65/0005

Страница 1: ...HIRSCHMANN LENGTH ANGLE RADIUS LOAD INDICATING SYSTEM EI65 0005 OPERATOR S MANUAL P N 056 065 190 005 Rev C 6 15 00...

Страница 2: ......

Страница 3: ...for a particular purpose PAT shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this manual This docume...

Страница 4: ......

Страница 5: ...iguration of the Crane 10 4 2 1 Setting of Reevings 13 4 2 2 Selecting the Hoist Winch 13 4 3 Activating and Setting of Preset Limits 14 4 3 1 Setting of Boom Length Presets 14 4 3 2 Setting of Boom A...

Страница 6: ......

Страница 7: ...g and calibration information Always refer to operational instructions and load charts provided by the crane manufacturer for specific crane operation and load limits 2 WARNINGS The EI65 is an operati...

Страница 8: ...on After ignition of the engine the system starts with an automatic test of all lamps the audible alarm and the complete system After the system has passed through the system test without errors the s...

Страница 9: ...c doc 3 Figure 1 PAT System EI65 Components of the Telescopic Crane 1 Console 2 Cable Reel 3 Linerider or Force Transducer 4 A2B Switch The load sensor depends on the system and crane options Refer to...

Страница 10: ...oc 4 Figure 2 PAT System EI65 Components of the Lattice Crane 1 Console 2 Cable Reel 3 Linerider or Force Transducer 4 A2B Switch 5 Angle Sensor The load sensor depends on the system and crane options...

Страница 11: ...The operating console is located in the operator s cabin in front of the operator This unit contains different displays and controls which are described in Section 3 3 Figure 3 Operating Console 1 Ove...

Страница 12: ...rm light in the button Horn Off 5 will light up The following crane movements will be stopped simultaneously hoist up telescope out boom down Option 3 Limit Alarm Light The Limit Alarm Light 3 will li...

Страница 13: ...setting the reevings and selecting the hoist winch is described in Section 4 2 8 Limit Button The button Limit 8 is used for activating the setting procedure of the preset limits The limits are define...

Страница 14: ...ing procedure of limits and operating conditions 13 Data Display The Display 13 will show technical information as well as operating information and instructions for the operator 120 0 112000l bs 88 5...

Страница 15: ...ith the actual crane configuration If there is a difference between the indicated and the actual condition the operator must correct those values by completing Steps 1 to 15 in Section 4 2 The system...

Страница 16: ...pped with a boom extension If the crane is equipped only with a main boom without jib or boom extension the OK 10 button has to be pressed Step 5 to 9 will be skipped when the button OK is pressed Ste...

Страница 17: ...by pressing the OK 10 button Step 9 The display shows the previously programmed or default offset of jib 2 Enter a new jib offset using the UP 12 or DOWN 11 buttons Confirm jib 2 offset by pressing th...

Страница 18: ...to review the selection made in the programming procedure press OK 10 button The display will show jib length and offset check correct and press OK If no jibs were selected the Exit screen will appea...

Страница 19: ...n OK 10 the procedure for Number of Reevings is completed The operating screen will be displayed which shows the measured crane data Complete Section 5 PRE OPERATION INSPECTION to ensure the data show...

Страница 20: ...on option When the system is longer than 2 hours without supply voltage the preset values may be lost and will reset to the to the maximum or minimum limits To activate a preset limit press the LIMIT...

Страница 21: ...l through the limits To set a minimum and maximum boom angle limit press the OK 10 button Step 2 The minimum boom angle preset value is displayed use the UP 12 and DOWN 11 buttons to change the displa...

Страница 22: ...us presets are displayed If the values are incorrect press OK 10 button and restart the limit preset procedure Pressing OK will store the preset values and return to the working screen 4 3 4 Setting o...

Страница 23: ...um boom load preset value is displayed use the UP 12 and DOWN 11 buttons to change the displayed value to your desired limit Pressing OK will store the preset value and return to the working screen 4...

Страница 24: ...on properly by lighting the red warning light sounding the audible alarm and locking the dangerous crane movements a Check the anti two block alarm light 2 and the audible alarm by manually lifting th...

Страница 25: ...lues an authorized PAT service representative shall be called for repair of the system and or verification of the crane s calibration Any structural modifications or changes to the crane shall require...

Страница 26: ...hanical parts and cables all other repairs shall be performed by PAT Authorized Service Representatives 8 TROUBLESHOOTING In case of a malfunction of the system a code that identifies the system malfu...

Страница 27: ...n aux Hoist 71 Limit Length Main Boom Max Decrease length limit 72 Limit Length Main Boom Min Increase length limit 73 Limit WG Main Boom Max Decrease main boom angle 74 Limit WG Main Boom Min Increas...

Страница 28: ...Operator s Manual EI65 0005 PAT Rev C 06 15 00 CSH 056 065 190005_c doc 22 HANDBOOK REVISIONS REV DATE NAME DESCRIPTION C 06 15 00 CSH Create Word DOC file from 056 065 060 005 Operator s Handbook...

Отзывы: