![Hirschmann PAT EI65/0005 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/hirschmann/pat-ei65-0005/pat-ei65-0005_operators-manual_2138144022.webp)
Operator’s Manual
EI65 / 0005
© PAT
Rev. C 06/15/00 // CSH
056-065 / 190005_c.doc
16
4.3.3 Setting of Boom Radius Presets
Step 1
This message appears after pushing the “LIMIT” (8) button and pressing
the “DOWN” (11) button to scroll through the limits. To set a minimum
and maximum boom radius limit press the “OK” (10) button.
Step 2
The minimum boom radius preset value is displayed, use the “UP” (12)
and “DOWN” (11) buttons to change the displayed value to your desired
limit. Push Button “OK” (10) for next step.
Step 3
The maximum boom radius preset value is displayed, use the “UP” (12)
and “DOWN” (11) buttons to change the displayed value to your desired
limit. Push Button “OK” (10) for next step.
Step 4
Verification of the previously set values for maximum and minimum
boom radius presets are displayed. If the values are incorrect press
“OK” (10) button and restart the limit preset procedure. Pressing “OK”
will store the preset values and return to the working screen.
4.3.4 Setting of Boom Height Presets
Step 1
This message appears after pushing the “LIMIT” (8) button and pressing
the “DOWN” (11) button to scroll through the limits. To set a minimum
and maximum boom height limit press the “OK” (10) button.
Step 2
The minimum boom height preset value is displayed, use the “UP” (12)
and “DOWN” (11) buttons to change the displayed value to your desired
limit. Push Button “OK” (10) for next step.
Step 3
The maximum boom height preset value is displayed, use the “UP” (12)
and “DOWN” (11) buttons to change the displayed value to your desired
limit. Push Button “OK” (10) for next step.
RADIUS LIMIT?
PUSH
↓
OR OK
MIN. LIMIT: 0.0
USE
↑↓
OR OK
MAX. LIMIT: 190
USE
↑↓
OR OK
MAX. LIMIT: 190
MIN. LIMIT: 0.0
HEIGHT LIMIT?
PUSH
↓
OR OK
MIN. LIMIT: 0.0
USE
↑↓
OR OK
MAX. LIMIT: 190
USE
↑↓
OR OK