Flowcharts
Rev A 05/01/01 // SB
190113_A
5
ERRO
R
CODE
ERROR
CAUSE
ACTION
E11
Fallen below limit for
the measuring channel
“length”.
a.) Cable between length
sensor and central unit
defective, not connected or
water in the connectors.
b.)Length sensor
Potentiometer defective.
c.)Electronic board in the
measuring channel
defective.
Refer to Section 3.7
a.)Check cable and connector
b.) Check and reset length
sensor Potentiometer. Refer to
Procedure 5.
c.) Check signal on main board
and analog input module.
E12
Fallen below lower limit
value for the
measuring channel
“pressure transducer
piston side”.
a.) Cable leading from the
central unit to the pressure
transducer defective, loose
or water in the connector.
b.)Pressure transducer on
piston side defective.
c.)Electronic component in
the measuring channel
defective.
Refer to Section 3.9
a.)Check cable and connector
b.)Check pressure transducer
and reset pressure channel.
c.) Check signal on main board
and analog input module.
E13
Fallen below lower limit
value for the
measuring channel
“pressure transducer
rod side”.
a.)Cable leading from the
central unit to the pressure
transducer defective, loose
or water in the connector.
b.)Pressure transducer on
rod side defective.
c.)Electronic component in
the measuring channel
defective.
Refer to Section 3.9
a.)Check cable and connector
b.) Check pressure transducer
and reset pressure channel.
c.) Check signal on main board
and analog input module.
E14
Fallen below lower limit
value for the
measuring channel
“force”.
a.)Cable leading from the
central unit to the pressure
transducer defective, loose
or water in the connector.
b.)Force transducer
defective. c.)Electronic
component in the measuring
channel defective.
a.) Check cable and connectors
as well and replace, if necessary.
b.)Check force transducer.
c.) Check signal on main board
and analog input module.
E 15
Fallen below lower limit
value for the
measuring channel
“angle main boom”.
a.)Cable from central unit to
the length/angle sensor
defective or loose.
b.)Angle sensor defective.
c.)Electronic component in
the measuring channel
defective.
Refer to Section 3.8
a.) Check cable.
b.) Check angle sensor and reset
adjustment. Refer to Procedure 5
c.) Check signal on main board
and analog input module.