Installation OCTOPUS 8M/16M/24M/OS32
Release 11 01/2013
3
Basic set-up
The IP parameters must be entered when the device is installed for the first
time. The device provides 6 options for configuring IP addresses:
Entry via V.24 connection
Entry using the HiDiscovery protocol via the application HiDiscovery or
Industrial HiVision
Configuration via BOOTP
Configuration via DHCP
Configuration via DHCP Option 82
Auto Configuration Adapter
Note:
Applies for the device variants OCTOPUS ...Train BP:
Avoid the use of the ring manager function for port 4 and port 8 (relay
ports).
Deactivate the Spanning Tree Protocol if you use the relay ports as data
rate 10 Mbits/s.
Use the same port configuration for the relay ports.
The device features the following options:
Auto-negotiation with autocrossing
MDI or MDIX
Half duplex or full duplex
10 Mbit/s or 100 Mbit/s
Test the device configuration for flawless operation by switching off the
current to the devices connected via relay ports.
Further information on the basic settings of the device can be found in the
“Basic Configuration” user manual on the CD/DVD.
WARNING
UNINTENTIONAL OPERATION IN DEVICE
Install and maintain a process that assigns a unique IP address to every
device in the network.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.