38
Installation OCTOPUS 8M/16M/24M/OS32
Release 11 01/2013
EMC and immunity
EMC compliance – IEC/EN 61000-6-2:2005 EMI TYPE tests, test acc. to:
IEC/EN 61000-4-2 Electrostatic discharge
Contact discharge
Air discharge
6 kV
8 kV
IEC/EN 61000-4-3 Electromagnetic field
80 MHz ... 2700 MHz
10 V/m
IEC/EN 61000-4-4 Fast transients (burst)
Power line
Data line
4 kV
4 kV
IEC/EN 61000-4-5 Voltage surges
Power line, line / line
Power Line, line / ground
Data line
1 kV
2 kV
1 kV
IEC/EN 61000-4-6 Conducted disturbances
150 kHz ... 80 MHz
10 V
EN 61000-4-9
Impulse-shaped magnetic fields
(only OCTOPUS... Train)
300 A/m
EMC interference emission
EN 55022
Class A
Yes
FCC 47 CFR Part 15 Class A
Yes
German Lloyd
Classifi Construction Guidelines VI-7-3 Part 1
Ed.2001
(only for the OCTOPUS 8M, OCTOPUS 16M and
OCTOPUS 24M devices)
Yes
Stability
Vibration
IEC 60068-2-6 Test FC test level according to IEC 61131-2 Yes
Germanischer Lloyd Guidelines for the Performance of Type
Tests Part 1
Yes
IEC 870-2-2 table 3 normal installation according to EN
61850-3
Yes
EN 61373, Category 1, Class A (broadband noise),
installation in acc. with EN 50155
Yes
Shock
IEC 60068-2-27 Test Ea test level according to IEC 61131-2 Yes
IEC 870-2-2 table 3 normal installation according to EN
61850-3
Yes
EN 61373, Category 1, Class A (broadband noise),
installation in acc. with EN 50155
Yes