18
Installation OCTOPUS 8M/16M/24M/OS32
Release 11 01/2013
1.5.5
“FAULT” signal contact
The potential-free signal contact (relay contact, closed circuit) reports
through a break in contact:
The failure of at least one supply voltage.
The device is not operational.
The failure of the connection on at least one port.
The report of the link status can be masked by the Management for each
port. In the delivery state, is deactivated.
Failure of the ring redundancy reserve.
Errors detected during the self-diagnostic test.
Incorrect configuration of the HIPER-Ring or ring coupling.
The following condition is also reported in RM mode:
Ring redundancy reserve is available. On delivery, there is no ring
redundancy monitoring.
You can also use the Management to set the signal contact manually and
thus control external devices.
1.5.6
ACA interface (ACA21-M12)
The ACA socket has an interface for the local connection of an
AutoConfiguration Adapter ACA 21-M12. It is used for saving/loading the
configuration and diagnostic functions, and for loading the software.
The ACA interface is a shielded 5-pin M12 socket with A coding.
Note:
The AutoConfiguration adapter available for certain Hirschmann
devices
ACA11
-M12 is not designed to be used with OCTOPUS
8M/16M/24M/OS32 devices.
Figure
Pin
Function
1
U
in
USB 5 V
2
N.C. Not
used
3
D
−
Data
−
4
GND Ground (0 V)
5
D+
Data +
Table 5:
Pin assignment of the ACA21-12 (M12 socket)