Installation OCTOPUS 8M/16M/24M/OS32
Release 11 01/2013
27
2.7
Connecting the data lines
You can connect terminal devices and other segments at the ports of the
device via twisted pair cables.
Use a shielded CAT5 cable or better.
Use shielded M12 connectors.
Note:
Only connect the PoE connections to PoE-supplier devices whose
data connections are located in the interior of the building and are specified
as SELV circuits.
Note:
Applies for the device variants OCTOPUS ...Train BP:
For coupling using relay ports, the maximum permitted overall length of all
cable segments between the actively communicating devices is 100 m.
Exceeding the maximum overall length compromises the data
communication.
Install the data lines according to your requirements.
Connect the cable shield to the connector housing.
Seal all unused connections and ports with locking screws (available as
accessories).