OCTOPUS 8M/16M/24M/OS32

Release 10 05/2012

CE marking

The devices comply with the regulations contained in the following 
European directive(s): 

2004/108/EC
Directive of the European Parliament and the council for standardizing 
the regulations of member states with regard to electromagnetic 
compatibility.

In accordance with the above-named EU directive(s), the EU conformity 
declaration will be at the disposal of the relevant authorities at the 
following address:

Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
Tel.: +49 (0)1805 14-1538

The product can be used in the industrial sector.

Interference immunity: EN 61000-6-2:2005

Emitted interference: EN 55022:2010

 

Warning!

 This is a class A device. This device can cause interference in 

living areas, and in this case the operator may be required to take 
appropriate measures.

Note: 

The assembly guidelines provided in these instructions must be 

strictly adhered to in order to observe the EMC threshold values.

FCC note:

This device complies with part 15 of the FCC rules. Operation is subject 
to the following two conditions : (1) This device may not cause harmful 
interference; (2) this device must accept any interference received, 
including interference that may cause undesired operation.
Appropriate testing has established that this device fulfills the 
requirements of a class A digital device in line with part 15 of the FCC 
regulations.
These requirements are designed to provide sufficient protection against 
interference when the device is being used in a business environment. 
The device creates and uses high frequencies and can also radiate high 
frequencies, and if it is not installed and used in accordance with this 
operating manual, it can cause radio transmission interference. The use 
of this device in a living area can also cause interference, and in this case 
the user is obliged to cover the costs of removing the interference.

Содержание OCTOPUS 16M-8PoE-2FX

Страница 1: ...11 12 13 14 15 16 17 18 P1 P2 RM FAULT V 24 ACA Power 1 2 P Managed ETHERNET Switch x y OCTOPUS OS32 Produktcode IP ADDRESS Function Pin 1 2 3 4 TX RX N C GND 3 4 1 2 1 2 3 4 5 48V DC 48V DC Function...

Страница 2: ...cribed here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s k...

Страница 3: ...er Ethernet 14 2 Assembly and start up 17 2 1 Installing the device 17 2 1 1 Unpacking and checking 17 2 1 2 Installing the SFP modules optional 17 2 1 3 Connecting the connector for supply voltage an...

Страница 4: ...4 OCTOPUS 8M 16M 24M OS32 Release 10 05 2012...

Страница 5: ...sonal injury if the instructions are not followed This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid...

Страница 6: ...ed pro perly and correctly Furthermore it must be operated and serviced carefully Warning Do not use the device in safety related applications in particular where life and limb may be in danger Supply...

Страница 7: ...es certified for hazardous locations Power input and output I O wiring must be in accordance with Class I Division 2 wiring methods Article 501 4 b of the National Electrical Code NFPA 70 and in accor...

Страница 8: ...iar with the setup assembly startup and operation of this product and are appropriately qualified for their job This includes for example those persons who have been trained or directed or authorized...

Страница 9: ...rsonnel trained for this purpose Relevant for OCTOPUS 16M 2FX OCTOPUS 16M 8PoE 2FX OCTOPUS 24M 2FX OCTOPUS OS32 08xx02O6O6 Note LED or LASER components in compliance with IEC 60825 1 2007 CLASS 1 LASE...

Страница 10: ...s Note The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC threshold values FCC note This device complies with part 15 of the FCC rules Opera...

Страница 11: ...ncy of the switching operations Check the resistance of the closed relay contacts and the switching function depending on the frequency of the switching operations Hirschmann is continually working to...

Страница 12: ...undancy Configuration user manual Graphical User Interface reference manual Command Line Interface user manual The Industrial HiVision Network Management Software provides you with additional options...

Страница 13: ...ice variant you can choose various media to connect terminal devices and other infrastructure components twisted pair cable multimode F O singlemode F O There are convenient options for managing the d...

Страница 14: ...2FX OCTOPUS 24M OCTOPUS 24M Train OCTOPUS 24M 2FX The OCTOPUS Train devices meet the requirements of EN 50155 Railway applications electronic systems in railway vehicles 1 2 2 Devices with Power over...

Страница 15: ...e individual ports are not electrically insulated from each other The following conditions are met in accordance with IEEE 802 3af Endpoint PSE Alternative A Device Number of FX ports Number of TX por...

Страница 16: ...on Pin 1 2 3 4 5 0V FAULT 3 4 2 1 TP Ports 3 4 5 6 7 8 9 10 3 4 5 6 7 8 9 10 TP Ports 3 4 2 1 P1 P2 RM FAULT V 24 ACA Power 1 2 3 4 5 Function Pin 1 2 3 4 TX RX N C GND Produktcode IP ADDRESS 3 4 1 2...

Страница 17: ...1 Installing the device 2 1 1 Unpacking and checking Check that the contents of the package are complete see page 39 Scope of delivery Check the individual parts for transport damage 2 1 2 Installing...

Страница 18: ...rtightness of the OCTOPUS 8M 16M 24M OS32 device only use voltage supply cables with a diameter within the specified range Connecting the supply voltage Redundant power supplies can be used Both input...

Страница 19: ...DC for 1 min Output power 150 W Current limitation 5 A Power supply unit and PoE media module form a limited power source according to IEC 60950 1 The external PoE power supply unit must be able to p...

Страница 20: ...ivated The loss of ring redundancy reserve A detected error during the self test Incorrect configuration of the HIPER Ring or ring coupling The following condition is also reported in RM mode Ring red...

Страница 21: ...in a location where the climatic threshold values specified in the technical data are adhered to Make sure the environment does not heat the device It can be mounted on temperature isolating material...

Страница 22: ...22 OCTOPUS 8M 16M 24M OS32 Release 10 05 2012 Figure 3 Dimensions of the following devices OCTOPUS 8M shown in fig OCTOPUS 8M Train OCTOPUS 8M 6PoE OCTOPUS 8M 8PoE...

Страница 23: ...012 23 Figure 4 Dimensions of the following devices OCTOPUS 16M OCTOPUS 16M Train OCTOPUS 16M 2FX shown in fig OCTOPUS 16M 8PoE OCTOPUS 16M 8PoE 2FX OCTOPUS OS32 080802T6T6TPEPHH OCTOPUS OS32 080802O6...

Страница 24: ...16M 24M OS32 Release 10 05 2012 Figure 5 Dimensions of the following devices OCTOPUS 24M OCTOPUS 24M 8PoE OCTOPUS 24M Train OCTOPUS 24M 2FX shown in fig OCTOPUS OS32 081602T6T6TPEPHH OCTOPUS OS32 081...

Страница 25: ...twisted pair cables 10 100 Mbit s twisted pair connection 4 pin M12 connector 10 100 Mbit s ports enable the connection of terminal devices or independent network segments according to the IEEE 802 3...

Страница 26: ...duplex mode 10 Mbit s half duplex mode 10 Mbit s full duplex mode Power over Ethernet PoE Delivery state autonegotiation activated The socket housing is electrically connected to the housing The PoE...

Страница 27: ...is electrically connected to the housing Install the data lines according to your requirements Use a shielded CAT5 cable or better Use a shielded 8 pin M12 plug Connect the cable shield to the connec...

Страница 28: ...g port 1 TX 1 RX 2 RX 2 TX 3 TX 3 RX 4 RX 4 TX M12 4 pin on RJ45 crossed MDI to MDI terminal device 1 TX 3 RX 2 RX 1 TX 3 TX 6 RX 4 RX 2 TX M12 4 pin on RJ45 1 1 MDI to MDI X Switch 1 TX 1 RX 2 RX 3 T...

Страница 29: ...the use of SFP modules see page 17 Installing the SFP modules optional OCTOPUS OS32 08xx02O6O6TPEPH1 The SFP slots are occupied with Fast Ethernet transceivers M Fast SFP SM LC EEC 2 2 Display elemen...

Страница 30: ...nfiguration via DHCP LED Display Color Activity Meaning P1 Supply voltage 1 Green Lights up The supply voltage is on None The supply voltage is too low P2 Supply voltage 2 Green Lights up The supply v...

Страница 31: ...cal 100 Mbit s ports 100 Mbit s full duplex All other ports autonegotiation Ring manager disabled ACA interface ACA21 M12 The ACA socket has an interface for the local connection of an AutoConfigurati...

Страница 32: ...certain Hirschmann devices AutoConfiguration Adapter ACA11 M12 is not designed to be used with OCTOPUS 8M 16M 24M OS32 devices Always use the ACA21 M12 if you want to use an AutoConfiguration Adapter...

Страница 33: ...e fig 8 Figure 8 SFP mounting tool 1 mounting side 2 barbed hooks 3 disassembly side Insert the SFP mounting tool into the SFP module so that the barbed hooks point to the base plate of the device and...

Страница 34: ...Train OCTOPUS 24M 8PoE 2 540 g OCTOPUS 24M 2FX 2 570 g OCTOPUS OS32 0816 2 700 g Operating voltage OCTOPUS without PoE Safety extra low voltage SELV PELV redundant inputs disconnected Relevant for Nor...

Страница 35: ...ltage max 60 V DC or max 30 V AC SELV Climatic conditions during operation Surrounding air temperature 40 F 158 F 40 C 70 C Humidity 10 100 condensing Air pressure minimum 795 hPa 2000 m maximum 1060...

Страница 36: ...s 150 kHz 80 MHz 10 V EN 61000 4 9 Impulse shaped magnetic fields only OCTOPUS Train 300 A m EMC emitted interference EN 55022 Class A Yes FCC 47 CFR Part 15 Class A Yes German Lloyd Classification Co...

Страница 37: ...0 29 dB 47 104 km 0 25 dB km 19 ps nm km LH LC SM 1550 nm 9 125 m 10 29 dB 55 140 km 0 18 dB kmb b with ultra low loss optical fiber 18 ps nm km Table 12 Fiber port 100BASE FX SFP fiber optic Fast Eth...

Страница 38: ...n PD powered device 8 Class0 PD 17 0 W 150 0 W 58 Btu IT h 79 Btu IT h OCTOPUS 24M 13 5 W 46 Btu IT h OCTOPUS24M Train 13 5 W 46 Btu IT h OCTOPUS 24M 2FX 14 9 W 51 Btu IT h OCTOPUS 24M 8PoE non PD pow...

Страница 39: ...request Device Scope of delivery OCTOPUS 8M OCTOPUS 8M Train OCTOPUS 8M 8PoE OCTOPUS 8M 6PoE OCTOPUS 16M OCTOPUS 16M Train OCTOPUS 16M 8PoE OCTOPUS 16M 2FX OCTOPUS 16M 8PoE 2FX OCTOPUS 24M OCTOPUS 24M...

Страница 40: ...able for use within an IP67 area Device Order number OCTOPUS 8M 943 931 001 OCTOPUS 8M Train 943 983 001 OCTOPUS 8M 8PoE 943 967 001 OCTOPUS 8M 6PoE 943 967 101 OCTOPUS 16M 943 912 001 OCTOPUS 16M Tra...

Страница 41: ...8 pin X coded Length 1 m Length 2 m Length 5 m 942 081 001 942 081 002 942 081 003 Transition M12 D coded to RJ45 934 498 001 Locking screw set 25 pcs 942 057 001 SFP mounting tool for IP67 socket 942...

Страница 42: ...s in railway vehicles EN 55022 IT equipment radio interference characteristics EN 61000 6 2 Generic norm immunity in industrial environments EN 61131 2 Programmable logic controllers FCC 47 CFR Part 1...

Страница 43: ...E mail inet ap belden com Hirschmann Competence Center The Hirschmann Competence Center is ahead of its competitors Consulting incorporates comprehensive technical advice from system evaluation throu...

Страница 44: ......

Отзывы: