![Hirschmann OCTOPUS 16M-8PoE-2FX Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/hirschmann/octopus-16m-8poe-2fx/octopus-16m-8poe-2fx_user-manual_2138107018.webp)
18
OCTOPUS 8M/16M/24M/OS32
Release 10 05/2012
Figure 2: Installing an SFP module
2.1.3
Connecting the connector for
supply voltage and signal contact
The supply voltage and the signal contact are connected by means of a 5-pin
M12 connector (A coding, e.g.
ELWIKA 5012 PG7 from Hirschmann, included in the delivery).
Note:
The permitted cable diameter for connector ELWIKA 5012 PG7 is
4 mm to 6 mm. To ensure the watertightness of the OCTOPUS 8M/16M/
24M/OS32 device, only use voltage supply cables with a diameter within the
specified range.
Connecting the supply voltage
Redundant power supplies can be used. Both inputs are uncoupled.
There is no distributed load. With redundant supply, the power supply unit
supplies the device only with the higher output voltage. The supply
voltage is electrically isolated from the housing.
With non-redundant supply of the main voltage, the device reports a loss
of power. You can avert this message by supplying the voltage over the
two inputs or changing the configuration in the management.